REFRIGERANT LEAK DETECTOR
INSTRUCTIONS
Install 4 Pieces”AAA”
alkline battery and press the
“ ” button to turn on.
6 seconds warm up time.
USE”+”or “-” button
to adjust 5 levels sensitivity.
USE”reset” button to
calibrate and continue
searching until the leak is
pinpointed.
WJL-6000Pro
/R
sales@aprvtiotech.comhttps://aprvtiotech.com/ +1 713 701 1986
Question and Answer IconNeed help?

Do you have a question about the APRVTIO WJL-6000 PRO and is the answer not in the manual?

APRVTIO WJL-6000 PRO Specifications

General IconGeneral
BrandAPRVTIO
ModelWJL-6000 PRO
CategorySecurity Sensors
LanguageEnglish

Summary

Instructions

Power On and Operation

Instructions for turning the device on, indicating normal function with a continuous beep.

Sensitivity Adjustment

Guidance on using +/- buttons to adjust sensitivity across 5 levels.

Calibration

Instructions to use the 'reset' button for calibration and continued leak detection.

Product Structure and Components

Device Components

Lists the key parts of the leak detector: sensing tip, probe, buzzer, display, buttons, and compartment.

Battery Installation Guide

Step 1: Remove Battery Rack

Procedure to open and take out the battery rack from the device.

Step 2: Install Batteries

Instruction to install four AAA alkaline batteries into the rack.

Step 3: Return Battery Rack

Guidance on returning the battery rack to its position in the device.

Device Setup and Operation

Powering On

How to turn the device on by pressing the power button.

Sensitivity Setup

Confirmation of successful sensitivity setup indicated by a flashing digital number.

Leak Detection

How the device indicates a detected leak via digital display and audible siren.

Technical Specifications

Operating Parameters

Details on operating temperature, maximum sensitivity, response time, and probe length.

Performance Metrics

Information on battery life, work mode, dimensions, warm-up time, and power supply.

Frequently Asked Questions (FAQ)

Continuous Beeping

Explanation for continuous beeping indicating normal operation, distinct from rapid leak detection beeps.

No Detection

Troubleshooting steps for when the detector does not detect a leak.

Low Battery Indicator

Meaning of the '6' display when battery voltage is low.

Sensor Error

Meaning of the 'E' display indicating a wet sensor needing attention.

Avoiding False Alarms

Methods to prevent false alarms by using automatic circuit or moving to open-air environment.

Siren Sound After Power On

Troubleshooting for persistent siren sounds, possibly due to high humidity, requiring a reset.

Important Notices and Precautions

Environmental Handling

Warnings against submerging in water or exposing to high temperatures/direct sunlight.

Maintenance and Cleaning

Instructions on keeping the sensing tip clean and proper cleaning methods with solvents.

Safety Precautions

Advice against dismantling the product and caution for electric shock when replacing parts.