EasyManua.ls Logo

APRVTIO WJL-6000 PRO - User Manual

APRVTIO WJL-6000 PRO
3 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
sales@aprvtiotech.comhttps://aprvtiotech.com/ +1 713 701 1986
WJL-6000 PRO
REFRIGERANT LEAK DETECTOR
INSTRUCTIONS
Install 4 Pieces”AAA”
alkline battery and press the
“ ” button to turn on.
6 seconds warm up time.
USE”+”or “-” button
to adjust 5 levels sensitivity.
USE”reset” button to
calibrate and continue
searching until the leak is
pinpointed.
WJL-6000Pro
/R
sales@aprvtiotech.comhttps://aprvtiotech.com/ +1 713 701 1986
Question and Answer IconNeed help?

Do you have a question about the APRVTIO WJL-6000 PRO and is the answer not in the manual?

Summary

Instructions

Power On and Operation

Instructions for turning the device on, indicating normal function with a continuous beep.

Sensitivity Adjustment

Guidance on using +/- buttons to adjust sensitivity across 5 levels.

Calibration

Instructions to use the 'reset' button for calibration and continued leak detection.

Product Structure and Components

Device Components

Lists the key parts of the leak detector: sensing tip, probe, buzzer, display, buttons, and compartment.

Battery Installation Guide

Step 1: Remove Battery Rack

Procedure to open and take out the battery rack from the device.

Step 2: Install Batteries

Instruction to install four AAA alkaline batteries into the rack.

Step 3: Return Battery Rack

Guidance on returning the battery rack to its position in the device.

Device Setup and Operation

Powering On

How to turn the device on by pressing the power button.

Sensitivity Setup

Confirmation of successful sensitivity setup indicated by a flashing digital number.

Leak Detection

How the device indicates a detected leak via digital display and audible siren.

Technical Specifications

Operating Parameters

Details on operating temperature, maximum sensitivity, response time, and probe length.

Performance Metrics

Information on battery life, work mode, dimensions, warm-up time, and power supply.

Frequently Asked Questions (FAQ)

Continuous Beeping

Explanation for continuous beeping indicating normal operation, distinct from rapid leak detection beeps.

No Detection

Troubleshooting steps for when the detector does not detect a leak.

Low Battery Indicator

Meaning of the '6' display when battery voltage is low.

Sensor Error

Meaning of the 'E' display indicating a wet sensor needing attention.

Avoiding False Alarms

Methods to prevent false alarms by using automatic circuit or moving to open-air environment.

Siren Sound After Power On

Troubleshooting for persistent siren sounds, possibly due to high humidity, requiring a reset.

Important Notices and Precautions

Environmental Handling

Warnings against submerging in water or exposing to high temperatures/direct sunlight.

Maintenance and Cleaning

Instructions on keeping the sensing tip clean and proper cleaning methods with solvents.

Safety Precautions

Advice against dismantling the product and caution for electric shock when replacing parts.

Overview

The WJL-6000 PRO is a sophisticated refrigerant leak detector designed for ease of use and compact portability. It incorporates advanced leak detection technology to identify halogenated refrigerants.

Function Description:

The primary function of the WJL-6000 PRO is to detect leaks of halogenated refrigerants. Upon activation, the device emits a continuous beep, indicating normal operation. When a refrigerant gas leak is detected, the audible tone changes to a rapid siren sound, and a digital result appears on the LED display. The device features an automatic circuit function that adjusts to changes in halogen gas concentration in the environment, helping to prevent false alarms. Users can also manually adjust the sensitivity to pinpoint leaks more accurately.

Important Technical Specifications:

  • Operating Temperature: 0 °C to 52 °C
  • Maximum Sensitivity: 3 gr/yr (grams per year) for all halogenated refrigerants. This indicates a high level of precision in detecting even small leaks.
  • Battery Life: Approximately 50 hours of normal use, providing extended operational time.
  • Response Time: Instant, allowing for immediate detection of leaks.
  • Work Mode: Continuous, with no limitations on usage duration.
  • Fixed Probe Length: 20 cm, offering good reach for various inspection points.
  • Dimension: 22.9 x 6.5 x 6.5 mm, highlighting its compact and portable design.
  • Warm-up Time: Approximately 6 seconds, ensuring quick readiness for use.
  • Power Supply: Requires 4 x 1.5V DC AAA batteries (not included).

Usage Features:

The WJL-6000 PRO is designed for straightforward operation:

  • Power On/Off: A short press of the power button turns the unit on or off. A continuous beep confirms the unit is functioning normally.
  • Sensitivity Adjustment: The device offers 5 levels of sensitivity, adjustable using the "+" or "-" buttons. This allows users to fine-tune the detector for different leak sizes and environmental conditions.
  • Calibration/Reset: A "reset" button is available to calibrate the device and continue searching for leaks, which is particularly useful for pinpointing the exact source of a leak. If the detector continuously sounds like a siren after power on, especially in high humidity, pressing and holding the power button for three seconds will reset it.
  • Battery Installation: The battery compartment is easily accessible. Users open the device, take out the battery rack, install 4 AAA batteries, and then return the rack to the device.
  • Leak Detection Indication: Once the sensitivity is set, the digital number on the display will flash twice and return to 0, indicating readiness. When a leak is detected, a result appears on the digital display, and the audible tone changes to a siren sound.
  • False Alarm Prevention: The automatic circuit function helps to avoid false alarms by adapting to environmental changes. For persistent false alarms, moving the device to an open-air environment, restarting it, and adjusting sensitivity to the maximum level is recommended.

Maintenance Features:

Proper maintenance ensures the longevity and accuracy of the WJL-6000 PRO:

  • Battery Management: Batteries should be removed when the device is not in use for extended periods to prevent leakage and damage. If the LCD screen displays "6", it indicates that the battery voltage is below an acceptable operating level, and batteries should be replaced.
  • Sensing Tip Care: The sensing tip must be kept clean from dust, moisture, and grease. If dirty, it can be cleaned by immersing it in a mild solvent like alcohol for a few seconds, then drying it with compressed air or a towel.
  • Prohibited Cleaning Agents: Do not use harsh solvents such as gasoline, turpentine, or mineral spirits to clean the product, as these can cause damage.
  • Sensor Wetness: If the LCD screen displays "E", it means the sensor is too wet. In this case, the sensor should be removed, blown dry, and reinstalled.
  • Safety Precautions:
    • Do not submerge the product in water.
    • Avoid exposing the product to temperatures exceeding 60°C.
    • Do not leave the product in direct sunlight for long periods.
    • Do not dismantle or attempt repairs without authorization.
    • Always turn off the tool before replacing the sensing tip to prevent mild electric shock.

APRVTIO WJL-6000 PRO Specifications

General IconGeneral
BrandAPRVTIO
ModelWJL-6000 PRO
CategorySecurity Sensors
LanguageEnglish

Related product manuals