8.1 QT2 3-Phase Microinverter Datasheet
Region
APAC
Model
QT2
Input Data (DC)
Recommended PV Module Power (STC) Range
315Wp-670Wp+
Peak Power Tracking Voltage
30V-45V
Operating Voltage Range
26V-60V
Maximum Input Voltage
60V
Maximum Input Current
20A x 4
Output Data (AC)
Maximum Continuous Output Power
2000VA
Nominal Output Voltage/Range
(1)
380V/324V-468V
Adjustable Output Voltage Range
305V-478V
Nominal Output Current
3.03Ax3
Nominal Output Frequency/Range
(1)
50Hz/48-51Hz or 60Hz/59.3-60.5Hz
Adjustable Output Frequency Range
45Hz-65Hz
Power Factor(Default/Adjustable)
0.99/0.8 leading...0.8 lagging
Maximum Units per 4mm
²
branch
(2)
9
AC Bus Cable
4mm
²
(28A)
Efficiency
Peak Efficiency
96.5%
Nominal MPPT Efficiency
99.5%
Night Power Consumption
40mW
Mechanical Data
Operating Ambient Temperature Range
(3)
-40 °C to +65 °C
Storage Temperature Range
-40 °C to +85 °C
Dimensions (W x H x D)
359mm X 242mm X 46mm
Weight
6kg
DC Connector Type
Stäubli MC4 PV-ADBP4-S2&ADSP4-S2
Cooling
Natural Convection - No Fans
Enclosure Environmental Rating
IP67
Features
Communication (Inverter To ECU)
(4)
Encrypted ZigBee
Isolation Design
High Frequency Transformers, Galvanically Isolated
Energy Management
Energy Management Analysis (EMA) system
Warranty
(5)
10 Years Standard ; Extended Warranty Optional
Compliance
Compliance
IEC 62109-1; IEC 62109-2; IEC 61000-6-1,-2,-3,-4; IEC 61727;
IEC 62116; IEEE 1547; IEE 1547.1; AS 4777.3; MEA; PEA;
EN 62109-1; EN 62109-2; EN 61000-6-1; EN 61000-6-3;
EN 50549-1;
2022/06/27 Rev1.0
(1) Nominal voltage/frequency range can be extended beyond nominal if required by the utility.
(2) Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area.
(3) The inverter may enter to power de-grade mode under poor ventilation and heat dissipation installation environment.
(4) Recommend no more than 80 inverters register to one ECU for stable communication.
(5) To be eligible for the warranty, APsystems microinverters need to be monitored via the EMA portal.
Please refer to our warranty T&Cs available on global.APsystems.com.
© All Rights Reserved
Specifications subject to change without notice please ensure you are
using the most recent update found at global.APsystems.com.

Other manuals for APsystems QT2

Related product manuals