| Product Type | Microinverter |
|---|---|
| Operating Voltage Range | 16V-60V |
| Maximum Input Voltage | 60V |
| Power Factor | >0.99 |
| Total Harmonic Distortion (THD) | <3% |
| Enclosure Rating | IP67 |
| Number of MPP Trackers | 1 |
| Operating Temperature Range | -40°C to +65°C |
| Nominal Output Voltage | 230V |
| Nominal Output Frequency | 50Hz / 60Hz |
| Maximum Output Current | 1.3A |
| Cooling | Natural Convection |
General safety guidelines for electrical installations, handling, and maintenance of the microinverter.
Information on EMC compliance and measures to correct potential interference with radio or television reception.
Explanation of symbols used in the manual, including cautionary marks and definitions for qualified personnel.
Lists accessories provided by APsystems for the microinverter installation, such as the EZ1 power cord.
Ensure the grid voltage aligns with the microinverter's rated specifications before installation.
Mount the microinverters securely on the rack or balcony, ensuring proper orientation and airflow.
Connect the APsystems microinverters to the respective PV modules, ensuring correct polarity and connection.
Connect the microinverter's AC connector to the provided EU power cord connector for grid connection.
Insert the connected power cord into the appropriate wall socket to complete the installation.
Instructions for downloading and installing the AP EasyPower application on iOS and Android devices.
Guide on connecting APsystems microinverters to the AP EasyPower app using Direct Connect or Remote Mode.
Details on monitoring real-time data, working status, cloud status, and system benefits via the AP EasyPower app.
Understanding operation LEDs (Start up, Operation, GFDI) for diagnosing microinverter status and errors.
Reference to an external guide for in-depth troubleshooting and fixing PV installations powered by APsystems microinverters.
Information on contacting APsystems local technical support for assistance with products and installation issues.
Note that APsystems microinverters do not require any specific regular maintenance procedures.
Step-by-step instructions for safely disconnecting, removing, and installing a replacement APsystems microinverter.
Detailed technical specifications for the EZ1-M and EZ1-H microinverter models, including input, output, and mechanical data.
Diagram showing the physical dimensions of the EZ1 microinverter accessory in millimeters.
Diagram illustrating the connection of a single APsystems microinverter with its accessories.
Diagram illustrating the connection of multiple APsystems microinverters in a system with accessories.