APsystems Microinverter EZ1 series User manual
15
8.1 EZ1 series Microinverter Datasheet
Model
EZ1-M
EZ1-H
Input Data (DC)
Recommended PV Module Power (STC) Range
300Wp-730Wp+
410Wp-760Wp+
Peak Power Tracking Voltage
28V-45V
Operating Voltage Range
16V-60V
Maximum Input Voltage
60V
Maximum Input Current
20A x 2
Isc PV
25A x 2
Maximum Inverter Backfeed Current To Array
0A
Output Data (AC)
Maximum Continuous Output Power
600VA
(3)
/ 799VA
960VA
Nominal Output Voltage/Range
(1)
230V/184-253V
Nominal Output Current
2.6A
(3)
/ 3.5A
4.2A
Nominal Output Frequency/ Range
(1)
50Hz/47.5Hz-51.5Hz
Power Factor
0.99
Inrush Current
11.92A
Maximum Output Fault Current
34A
Maximum Output Overcurrent Protection
10A
Efficiency
Peak Efficiency
97.3%
Nominal MPPT Efficiency
99.5%
Night Power Consumption
20mW
Mechanical Data
Operating Ambient Temperature Range
(2)
-40 °C to +65 °C
Storage Temperature Range
-40 °C to +85 °C
Dimensions (W x H x D)
263mm x 218mm x 36.5mm
263mm x 218mm x 37mm
Weight
2.8kg
3kg
DC Connector Type
Stäubli MC4 PV-ADBP4-S2&ADSP4-S2
Cooling
Natural Convection - No Fans
Enclosure Environmental Rating
IP67
Pollution Degree Classification
PD3
Operate Relative Humidity Range
4%~100%
Maximum Altitude
<2000m
Overvoltage Category
OVC Il For PV Input Circuit, OVC Ill For Mains Circuit
Power Cord(Optional)
Wire Size
1.5mm²
Cable Length
5M as default
Plug Type
Schuko
Features
Communication
Built-in Wi-Fi and Bluetooth
Maximum Units Can Be Connected
(4)
2
Isolation Design
High Frequency Transformers, Galvanically Isolated
Energy Management
AP EasyPower APP
Warranty
12 Years Standard; 20 Years Optional
Compliances
Safety, EMC & Grid Compliances
EN 62109-1/-2; EN 61000-1/-2/-3/-4; EN 50549-1; DIN V VDE V 0126-1-1; VFR;
UTE C15-712-1; CEI 0-21; UNE 217002; NTS; RD647; VDE-AR-N 4105
(1)Nominal voltage/frequency range can be extended beyond nominal if required by
the utility.
(2)The inverter may enter to power de-grade mode under poor ventilation and heat
dissipation installation environment.
(3)The factory setting could be 600VA as default and raise to 800VA after intallation
according to the regulation adjustment.
(4)For some countries it is limited to 1 because of the regulations.