Installation / User Manual
© All Rights Reserved
ALTENERGY POWER SYSTEM Inc.
global.APsystems.com
APsystems Shanghai China
Rm.B403 No.188, Zhangyang Road, Pudong, Shanghai
200120,P.R.C
TEL: 021-3392-8205 EMAIL: info.global@APsystems.com
APsystems DS3 series
(DS3-S,DS3-L, DS3, DS3-H)
Microinverters
(For NA)

Other manuals for APsystems DS3 Series

Question and Answer IconNeed help?

Do you have a question about the APsystems DS3 Series and is the answer not in the manual?

APsystems DS3 Series Specifications

General IconGeneral
TypeMicroinverter
Input Voltage Range16-60V
Operating Temperature Range-40°C to +65°C
Enclosure RatingIP67
AC Output Frequency50/60 Hz
Max. DC Input Voltage60V
Start-up Voltage16V
CoolingNatural Convection
Protection LevelIP67
ModelDS3
Output Voltage240V
CommunicationZigbee
MPPT Voltage Range22-48V
CEC Weighted Efficiency97.0%
AC Output Power800W
Max. AC Output Power880 VA
AC Output Voltage Range220-240V

Summary

Important Safety Instructions

1.1 Safety Instructions

Crucial safety instructions for installing and operating APsystems Microinverters.

1.2 Radio Interference Statement

FCC/IC compliance statement detailing potential radio frequency energy emissions.

1.3 Symbols replace words on the equipment, on a display, or in manuals

Explains the meaning of various symbols used throughout the manual and on the device.

APsystems Microinverter System Introduction

APsystems Microinverters maximize PV energy production

Explains how individual MPPTs in microinverters optimize energy harvest from each PV module.

More reliable than centralized or string inverters

Highlights the distributed nature of APsystems microinverters for enhanced system reliability.

Simple to install

Discusses the ease of installation for individual APsystems microinverters.

Smart system performance monitoring and analysis

Details the ECU and EMA for monitoring system performance and receiving alerts.

APsystems Microinverter DS3 Series Introduction

APsystems Microinverter System Installation

4.1 Additional Installation components from APsystems

Lists optional APsystems components required for installation.

4.2 Required Parts and Tools from you

Outlines the necessary parts and tools that the installer must provide.

4.3 PV Rapid Shut Down Equipment

Details requirements for PV Rapid Shut Down Equipment as per NEC standards.

4.4.1 Step 1 - Verify the grid voltage to match with microinverter rating

Verifying grid voltage compatibility with the microinverter specifications.

4.4.2 Step 2 - The AC bus distribution

Instructions for arranging and wiring the AC bus distribution.

4.4.3 Step 3 - Attach the APsystems Microinverters to the Racking

Guidance on mounting APsystems microinverters onto the PV racking system.

4.4.4 Step 4 - Ground the systems

Procedures for grounding the APsystems microinverter system.

4.4.5 Step 5 - Connect the APsystems microinverter to AC bus cable

Instructions for connecting the microinverter's AC connector to the AC bus cable.

4.4.6 Step 6 - Install a Bus Cable End Cap at the end of AC bus cable

Steps for installing the end cap on the AC bus cable for proper sealing.

4.4.7 Step 7 - Connect APsystems Microinverters to the PV Modules

Guide to connecting APsystems microinverters to the PV modules.

4.4.8 Step 8 - Complete the APsystems installation map

Instructions for filling out the APsystems installation map with serial numbers.

APsystems microinverter system operating instructions

Troubleshooting

6.1 Status Indications and Error Reporting

Explains LED status indicators and how errors are reported by the microinverters.

6.1.1 Start up LED

Description of the LED behavior during microinverter startup.

6.1.2 Operation LED

Details the meaning of different LED light patterns during operation.

6.1.3 GFDI Error

Information on identifying and resolving Ground Fault Detector Interrupter (GFDI) errors.

6.1.4 Other Faults

Guidance for other faults reported to the ECU.

6.2 Troubleshooting a non-operating APsystems Microinverter

Specific steps to troubleshoot microinverters that are not operating correctly.

6.3 Maintenance

Information regarding the maintenance requirements for the system.

Replace a microinverter

Technical Data

8.1 DS3 Series Microinverter Datasheet

Detailed technical specifications for the APsystems DS3 Series Microinverters.

Wiring Diagram

9.1 Sample Wiring Diagram - Single Phase

A sample wiring diagram for a single-phase APsystems microinverter setup.