EasyManua.ls Logo

APV W+ Series - 3 Warnings

APV W+ Series
18 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
GB
Form no.: L453147GB– revision 06/2013
3. Warnings
1. Readthroughtheinstructionsbeforeinstallingthepumpand
startingitup.Ifindoubt,contactyourlocalSPXFlowTechnology
representative.
2. Checkthatthespecicationsofthemotorandmotorcontrolunitare
correct.Thisappliesinparticulartoapplicationswhichcarryariskof
explosion.
3. Observethatapumpmaybeunstableandmaytilttotheforeontoits
inlet port when having a relatively small motor and being assembled
onbracketsinsteadofbeingequippedwithaframewithadjustable
feet.Becarefulduringtheinstallationofsuchapump.(Forthis
reason, the W+50/600 pump is equipped with an anti-tilting unit.)
4. Donotstartthepumpbeforeallpipeconnectionshavebeentted
carefullyandtightened.Specialprecautionsmustbetakenwhen
thepumpisusedtopumphotand/orhazardousliquids.Insuch
casesfollowthelocalregulationsforpersonalsafetywhenworking
withtheseproducts.
5. Donotstartthepumpbeforethemotorshroudorshaftguardhasbeen
securelytted.
6. Thepumpcontainsrotatingparts.Neverputyourhands,ngersor
objectsintoapumpwhileitisinoperation.
7. Nevertouchtheshroudduringoperation,asitcanbecomeveryhot.
8. Nevertouchthepumpbodyduringoperationifthepumpisbeingused
forhotmedia,asthereisariskofbeingburnt.
9. Ifthepumpisoperatingwithliquidmediabuthasnocirculation,the
liquidwillheatupandmayturnintovapour,whichcouldcausean
explosion.
10. Alwaysremoveallassemblyandauxiliarytoolsfromthepumpbefore
starting it up.
11. Neverhosedownorcleantheelectricmotordirectlywithwater
orcleaninguid.
12. Neverliftthepumpattheshroud,asitisnotdesignedtocarrythe
weightofthemotor.Removetheshroudbeforeliftingthepump.
Alwaysusesecurelyttedliftingstrapswhenliftingwithacrane
orsimilarliftinggear.
13. Neverdismantlethepumpbeforethemotorhasbeendisconnected
fromthepowersupply.Removethefusesanddisconnectthecable
fromthemotorterminalbox.
14. Theinstallationofallelectricalpartsmustbecarriedoutbyqualied
personnel.
4
APV

Other manuals for APV W+ Series

Related product manuals