EasyManua.ls Logo

Aqua-Base ESB 601 - Installation of Watermaker; Preparation; Placing the Unit; Electrical Connection

Default Icon
19 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
\\Serveurslce3\DAO\Etude-3d\Aquaset\0-DOSSIER TECHNIQUES\1-sw-plaisance\ESW\09- Manuels Utilisateur\DOC UTILISATEUR ESB FRUKES 2012-11-K.doc VERSION 2012-11-K FR/UK/ES Page 16/39
4 – INSTALLATION OF WATERMAKER
4.1 – PREPARATION
The hull fitting and the hull valve (V0) are supplied and installed by the shipyard.
The seawater feed hull fitting (EdM) should be placed as low as possible below the water line, in an area always immersed whatever the
boat’s navigation speed may be.
The hull valve (V0) should be placed on the seawater supply pipes (internal 20 diameter Embedded steel spirale reinforcement
), as close as
possible to the hull fitting.
The reject hull fitting (R) should be placed above the water line.
Î See installation on board in anexe
4.2 – PLACING THE UNIT
¾ The Hydraulic amplifier and membrane: The main module should be bolted onto a rigid surface. The main module can be
installed in either vertical or horizontal position.
¾ Seawater intake:
The through-hull must correspond to the size of the hoses, as specified in the installation diagram. The through-
hull must be installed as deep as possible, towards the middle of the boat. Extra care must be used if the Watermaker is operated
while the boat is moving because of the risk of running dry or having the pump cavitating.
¾ The sea strainer:
The sea strainer should be near to the hull valve and imperatively fully charged with seawater.
¾ The 5µ filter:
The filter should be installed using the provided support, vertically against a wall. If necessary, they can be slightly
tilted.
¾ The auxiliary tank:
This auxiliary tank (bucket) is used for rinsing, cleaning and preservation operation. See "Watermaker
shutdown".
¾ The low pressure pump (LP):
The Low Pressure pump (LP) should be installed between the sea strainer and the 5µ filter and
below the water line (at least 200mm) to avoid any trapped air. If this instruction is not followed, we cannot guarantee the good
operation of the unit.
4.3 – ELECTRICAL CONNECTION
- The AQUA-BASE unit is equipped with a circuit breaker ensuring its protection and security. This doesn’t ensure the
protection of your installation, which should be equipped with devices conforming to the current legislation.
- No other equipment should be fed from the AQUA-BASE UNIT box.
- Check beforehand that the unit voltage corresponds with the network.
If the wire is > 10m : contact your dealer
Warning : A decrease of wire section or an increase of length
create a loss of voltage in the terminals of the electric motor,
and a decrease in the performance of the system
(contact your dealer if necessary)
Maxi length:
10m
ESB301
12VCC
2 x 6mm²
15A maxi
ESB302
24VCC
2 x 6mm²
8A maxi
ESB601
12VCC
2 x 10mm²
40A maxi
ESB602
24VCC
2 x 6mm²
30A maxi

Related product manuals