Simpool Timer Model INSTRUCTION AND MAINTENANCE MANUAL
Programmable digital peristaltic pump ENGLISH
ADSP7000722 rev. 1.0 23/02/2017 47/64
From the Settings Menu you can carry out the following operations (refer to Figure 13):
Set the password to access the programming section PAS: with Enter you can go to the 000” selection
page, with the and keys you can increase/decrease the value displayed and with Enter you can scroll
to the figure you intend to set. After choosing the new password, press Enter for 3 seconds to go back to the
PAS entry;
Enable the pump stop in case of a P.St level alarm: to enter and exit the submenu, use the Enter key, use
the and ▼ keys to choose "YES/no";
Programme the current day of the week D.CL: use Enter to enter and exit the submenu and use the and
▼ keys to scroll to the Sun/Mon/Tue/Wed/Thu/Fry/Sat values;
Programme the hours of the current time H.CL: to enter and exit the submenu, use Enter, to scroll through
the values from 0 to 23 hours use the and ▼ keys;
Programme the minutes of the current time n.CL: to enter and exit the submenu, use Enter, to scroll through
the values from 0 to 59 seconds use the and ▼ keys;
Set the stabilization time of the inhibiting signal, Stb, coming from the swimming pool recirculation pump,
within a range of 0-999 seconds: to enter and exit the submenu, use Enter, to scroll through the values use
the and ▼ keys;
Set the time of the pump maintenance alarm, O.F.d, from 0 (disabled) to 999 hours, based on the following
format:
- h.mm up to 9 h and 59 m
- hh.m up to 99 h and 59 m (minutes expressed in tens)
- hhh up to 999 h
To enter and exit the submenu use Enter and increase/decrease the value with the and ▼ keys;
Access the In.t inhibiting signal recognition window: to enter and exit the submenu use Enter. The display
will show the status identified by the pump for the input signal:
Steady "HI": enabling signal identified as active;
Steady "Lo": enabling signal identified as not active;
Flashing “HI”: enabling signal identified as active, but slightly above the identification voltage threshold;
Flashing "Lo": enabling signal identified as not active, but slightly below the identification voltage threshold;
If the status displayed does not correspond to the actual status of the signal or if the status displayed is
flashing, just scroll with the and ▼ keys to change the threshold, namely:
Status of the non-active signal (recirculation pump OFF):
if the signal is identified as active (steady or flashing HI) or not active but near the threshold (flashing Lo),
press ▼ to reduce the threshold voltage until a steady “Lo” is displayed;
if the signal is permanently identified as not active (steady Lo), conduct a check when the signal is
activated;
Status of the non-active signal (recirculation pump ON):
if the signal is identified as not active (Lo steady or flashing), or active but near the threshold(flashing HI),
press to increase the threshold voltage until a steady “HI” is displayed;
if the signal is permanently identified as not active (steady HI), conduct a check when the signal is
disabled;
Enable or disable the inhibiting sign In.E : to enter and exit the submenu, use the Enter key, use the and
▼ keys to choose "YES/no";
Choose if you want to enable modification of the daily and weekly dosage calendar, OnL from the User
Menu: to enter and exit the submenu, use the Enter key, use the and ▼ keys to choose "YES/no";
Set the wait time of the inhibiting signal tn.A, that is the time frame, from the scheduled dosage time, within
which it is necessary to receive the stabilized recirculation pump signal to activate the product dosage: to
enter and exit the submenu, use the Enter key, use the and keys to scroll through the values from 0 to
60 minutes;