12
Parameter
Address
Description
Default
Setting
Setting Range
1
PIN3
100%
30-120%, by 5% increments
2
PIN2
80%
30-120%, by 5% increments
3
PIN1
40%
30-120%, by 5% increments
4
Backwash capacity
100%
80-120%, by 5% increments
5
Control mode of
Analog Input
0
0: current control
1: Voltage control
6
Enable or disable the
priming that occurs at
each start
25
25:enables 0: disables
7
Reserved
0
Not editable
8
System time
00:00
00:00 - 23:59
9
Preset 1 of the
skimmer mode
(skimmer cycle,
skimmer duration,
skimmer speed)
01:00
00:03
100%
Skimmer cycle: 1-24h, 1h for each step
Skimmer duration: 1-30min, 1min for
each step
Skimmer speed: 30%-100%, by 5%
increments
10
Time period of the
preset 1 of the
skimmer mode
7:00-21:00
Start time: 00:00-24:00
End time: 00:00-24:00
11
Speed limit
100%
60%-100%, by 5% increments
100% means no speed limit
12
RS485 address
170(0xAA)
160-190 (0xA0-0xBF),
each step by 1.
13
Time interval to trigger
the self-learning
automatically
0
0, 1, 3, 5, 7, 14, 21, 28 (day)
“0” means will not trigger the
self-learning automatically