AquaMaster
®
Owner’s Manual 1/21/2021 16
Four-Button Controller, Cont.
Button
Function
Set
Used to set Customer Settings
Change
Used to change Customer Settings
Power Clean
(5000 and 5100
only)
Activates/deactivates the powerClean™ feature, which is a service/maintenance step for water
supplies that have an excessive amount of iron. “powerClean™” will display when this feature is
activated. The appliance will regenerate every other day with five pounds (2.3 kg) of salt. Leave the
powerClean™ feature on for a minimum of two weeks. The frequent regeneration will eliminate iron
buildup in the resin bed. The use of salt with an iron cleaning agent or iron out cleaner is
recommended for continuous use as a preventive measure against iron fouling of the resin bed.
Use this feature every six months as a part of your routine maintenance procedure to ensure a long
service life for your water treatment appliance
Regenerate
Used when starting your water conditioner to start an immediate regeneration, or to restore
capacity if you run out of salt
To Start an Immediate Regeneration
11. Press and hold the Regenerate button for about five seconds.
12. The appliance is in regeneration mode and will display the status of each cycle.
13. After all regeneration cycles are complete, the display will return to normal operating
mode.
To Quickly Advance Through the Regeneration Cycles
(used when starting up or diagnosing the appliance only)
14. Press and hold the Regenerate button for about five seconds until the cycle begins.
15. The cycle position will display (for example, 01).
16. If the controller does not advance to the next cycle position after 20 seconds, press and
hold the Regenerate button until the cycle number changes (about 2 seconds).
Each cycle can be advanced by pressing the Regenerate button. Always wait until the cycle
position displays before advancing to the next cycle position.