Troubleshooting, Cont.
regeneration
Controller not attached properly
Make sure the controller is pushed all the way
onto the drive end cap
Foreign object in valve body
Remove foreign object(s) from the valve body
Broken valve assembly. Motor running
cabinet
Restricted, frozen, or pinched drain line
Remove restriction, thaw, or straighten drain
line
Plugged brine line, brine line flow control, or
air check/draw tube
Clean flow control, air check/draw tube, and
brine line. Clean any sediment from the brine
Plugged injector assembly
Clean or replace injector. Replace throat if
removed
Sticking brine refill valve
Remove valve. Check for obstruction
proper sequence
Replace injector screen, nozzle, and throat
Maintain minimum pressure of 20 psi (1.4 bar)
Drain line or flow control is restricted
Brine line restricted or crimped
Remove restriction, replace if crimped
Excessive amount of water in brine cabinet
Verify correct water level relative to salt
setting. Check lines and fittings for loose
Check mode setting chart for proper brine
rinse time. Adjust time, if necessary
Intermittent pressure drop from feed source
Install check valve on the inlet water line to the
appliance (Check local plumbing codes first)
Brine valve drips water back to brine cabinet
Clean brine valve housing, replace piston
assembly