Questions and Answers

  • C
    Charles TurnerSep 13, 2025
    Why is there no water coming from my AquaSure AS-PR75A Water System faucet?
    • J
      Jessica MullinsSep 14, 2025
      If there's little to no water at your AquaSure Water System dispensing faucet, first check if the water is shut off at the stop valve (open it). Also, ensure the Flowlok is in the open position (lever should be lowered). Other potential issues include a crimped output line (reroute it), a tank that isn't pre-charged (empty and recharge it), a defective tank (replace it), a tank that hasn't filled yet (allow it to refill), insufficient water pressure (install a booster pump or permeate pump), or incorrect installation (check the installation guide).
  • T
    Todd SchroederAug 27, 2025
    Why does my AquaSure AS-PR75A Water System tank take a long time to fill?
    • B
      Bradley ChangAug 27, 2025
      The AquaSure Water System tank might take a long time to fill due to: * Insufficient water pressure: Ensure incoming water pressure is above 40 psi. Install a booster pump or permeate pump. * Lower water temperature: Cold water affects system performance. Install a booster pump or permeate pump to compensate.
  • A
    April MorseAug 27, 2025
    How to fix drain water overflows at the air gap faucet in my AquaSure AS-PR75A?
    • A
      andrewbutlerAug 27, 2025
      Overflowing drain water at the air gap faucet in your AquaSure Water System can be caused by: * A clogged air gap: Clear the air gap. * A clogged drain line: Clear the tubing. * A drain flow rate that is too high: Replace the flow restrictor.
  • K
    katherinebrennanAug 29, 2025
    Why does my AquaSure AS-PR75A have taste and odors in product water?
    • C
      Carlos GoodmanAug 29, 2025
      Taste and odors in the product water of your AquaSure Water System can be caused by: * An exhausted carbon post filter: Replace the filters. * Foreign matter in the holding tank: Clean, flush, and sanitize the holding tank. Replace filters. * Reversed product water and drain water lines: Correct the plumbing. * Dissolved gases in feed water: Pre-treat feed water to remove gases. * Increase in product water TDS: See “Product water is high in total dissolved solids” for troubleshoot.
  • S
    Samantha GibsonAug 30, 2025
    What causes my AquaSure AS-PR75A Water System to make a humming noise?
    • R
      Randy CabreraAug 30, 2025
      The humming noise in your AquaSure Water System is caused by: * An air bubble trapped inside the housing: Purge the air by tilting the system on one side, shut off the tank ball valve, and turn on the dispensing faucet for about 1 minute. Repeat 3 or 4 times to purge out all the air.
  • S
    Samantha SmithSep 1, 2025
    Why does my AquaSure Water System faucet leak or drip?
    • M
      Marie ColeSep 1, 2025
      Leaks or drips in your AquaSure Water System faucet can occur due to: * Water leaks from faucet spouts: Adjust the faucet by turning the tee bar located under the handle to provide a small amount of free play in the handle when shut off. If this doesn't work, repair or replace the faucet. * Water leaks from beneath the handle: Repair or replace the faucet.
  • J
    Jessica GonzalezNov 21, 2025
    Why is there not enough water from the holding tank in my AquaSure AS-PR75A?
    • E
      Earl HerreraNov 21, 2025
      Several factors can cause insufficient water in your AquaSure Water System's holding tank: * A plugged feed water valve: Open or unclog the valve. * Clogged sediment/carbon pre-filters or carbon post filter: Replace the filters. * Low incoming water pressure: Ensure pressure is above the recommended PSI level, and install a booster or permeate pump if needed. * A fouled reverse osmosis membrane: Verify incoming water pressure is within limits, ensure the drain line isn't clogged, and replace the membrane. * Incorrect air pressure in the holding tank: Empty the tank and ensure the air pressure in the valve stem is between 5-10 psi. * A ruptured air bladder: Replace the holding tank. * A closed holding tank valve: Open the valve. * A clogged drain flow restrictor: Replace th...
  • P
    pkingNov 23, 2025
    What to do if my AquaSure Water System product water has high in total dissolved solids (TDS)?
    • R
      robertsonmichaelNov 24, 2025
      High total dissolved solids (TDS) in your AquaSure Water System's product water may be due to: * Clogged pre-filters: Replace the filter. * Low incoming water pressure: Ensure incoming water pressure is above 40 psi. Install a booster pump or permeate pump. * Expanded reverse osmosis membrane: Check the TDS level of incoming water. If it exceeds the recommended range, pretreatment may be needed. Replace the RO membrane. * Reversed product water and drain water lines: Check the connection and correct the plumbing. * Clogged drain flow restrictor: Replace the drain flow restrictor. * Clogged air gap faucet: Clear or replace the air gap faucet. * Automatic shut-off not closing: Repair or replace the automatic shut-off valve. * New carbon post-filter not rinsed completely: Dra...
  • C
    Casey OwensSep 12, 2025
    Why does my AquaSure AS-PR75A tank take so long to fill?
    • R
      Richard EdwardsSep 12, 2025
      If your AquaSure Water System's tank is taking a long time to fill, it could be due to insufficient water pressure. Ensure incoming water pressure is above 40 psi. If it's not, install a booster pump or permeate pump. Additionally, lower water temperature can affect the system's performance; consider installing a booster pump or permeate pump to compensate.
  • M
    michelle71Sep 9, 2025
    Why does my AquaSure Water System have high TDS?
    • J
      Joseph ArmstrongSep 9, 2025
      High total dissolved solids (TDS) in your AquaSure Water System's product water can be caused by several factors. Clogged pre-filters (replace them) or low incoming water pressure (install a booster pump or permeate pump) could be the issue. The reverse osmosis membrane might be expanded (replace the RO membrane), or the product and drain water lines could be reversed (check and correct the plumbing). Other potential causes include a clogged drain flow restrictor (replace it), a clogged air gap faucet (clear or replace it), a malfunctioning automatic shut-off (repair or replace it), a new carbon post-filter that hasn't been rinsed completely (drain the holding tank twice), or an increase in the incoming feed water TDS.

Summary

Inspection and Preparation

Be Familiar with the System Before Installation

Understand system components, operation parameters, and gather necessary tools before installation.

Feed Water Adapter with 3;8 and 1;2 Connection Setup

Quick Connect; Compression Fitting Installation Instruction

INSTALLING THE SYSTEM

Feed Water Adapter Installation

Step-by-step guide for connecting the system to the cold water supply valve.

Drain Saddle Installation

Instructions on how to install the drain saddle onto the sink's drain pipe.

Connecting the System

Detailed instructions on connecting all the tubing and components of the system.

System Startup

Procedures for turning on the system, filling the tank, and flushing the first batch of water.

SYSTEM MAINTENANCE

Filter Replacement Time Frame

Recommended schedule for replacing sediment, carbon, and RO membrane filters.

Replacing Stage 1 & 2 Pre-Filters

Step-by-step guide for replacing the initial sediment and carbon pre-filters.

Replacing Stage 3 & 4 RO Membrane and Post Carbon Filter

Instructions for replacing the RO membrane and post-stage taste refining filter.

SYSTEM TROUBLESHOOTING

Not Enough Water from Holding Tank

Common causes and solutions for low water flow from the storage tank.

Taste and Odors in Product Water

Identifies issues causing unpleasant taste or odor in the purified water and their fixes.

Low Water Pressure from Dispensing Faucet

Troubleshooting steps for low water pressure at the faucet.

Little to No Water at Dispensing Faucet

Troubleshooting steps for no or very low water flow from the faucet.

System Slow to Shut Off

Diagnosing and fixing issues where the system does not shut off promptly.

System Does Not Shut Off

Troubleshooting for the system failing to shut off completely.

MANUFACTURERS WARRANTY

AquaSure AS-PR75A Specifications

General IconGeneral
ModelAS-PR75A
CategoryWater System
Purification TechnologyReverse Osmosis
Stages5
Daily Production75 Gallons Per Day (GPD)
Storage Tank Capacity3.2 Gallons
Warranty1 Year Limited Warranty
TypeReverse Osmosis
Filter Life12 months
Included FiltersSediment, Carbon, RO Membrane, Post Carbon

Related product manuals