CD73 COMPACT DISC PLAYER
- 8 -
INSTRUCTION FOR HANDLING OPTICAL SYSTEM BLOCK PICK-UP
Electrostatic breakdown of the laser diode in the optical system block may occur due to a potential difference caused
by electrostatic charge accumulated on clothing, human body, etc. A ground must be provided as follows to prevent
any electrostatic charge during unpacking or repair work.
1. Ground for Human Body
Be sure to wear a ground band (1M ohm) that is properly to remove any static electricity that may be charged on the
body.
2. Ground for Work Bench
Be sure to place a conductive sheet (1M ohm) or copper plate with proper grounding on the work bench or other sur-
face on which the pick-up is to be placed.
3. Because the static electricity charge on the clothing does not discharge through the body grounding band, do not
let clothing to get in contact with the pick-up unit.
INCORRECT CORRECT
NOTE: Laser diodes are so susceptible to damage from
static electricity that even if a static discharge does not
ruin the diode, it can shorten its life or cause it to work
improperly.
1.Grounding band
1M ohm
1M ohm
2.Conductive Sheet
or Copper Plate
IMPORTANT NOTES
SHOW THE SOFTWARE VERSION
Press " I< "(TRACK), " STOP ", " I< "(TRACK) will show the software version under STOP mode with disc inside. It
will return to normal after 2 seconds.
JUMPER SETTING BETWEEN CD73 & CD83
Location
CD73 CD83
PL100 OPEN OPEN
PL202 OPEN SHORT
PL203 SHORT OPEN
PL204 OPEN SHORT
PL205 SHORT OPEN
PL300 1/2 SHORT 2/3 SHORT
PL400 SHORT OPEN
PL401 SHORT OPEN
PL402 SHORT OPEN
PL403 OPEN SHORT