OPTIMA 30-1 18
Press slightly and turn the control knob clockwise 3to the OFF position and wait 5
minutes; thus allowing any gases to escape which may have accumulated in the
combustion chamber.
Note: LP gases do not vent upward. Then follow step 2 and 3 to establish pilot.
OPERATION INSTRUCTIONS Cont..
Press and turn control knob counterclockwise 4to HIGH position.
Release knob. If pilot should go out, turn the control knob to OFF position and
repeat steps 1, 2 and 3.
Note: The control valve is equipped with an internal safety interlock. You must
leave at “off” position for about 5 minutes before lighting pilot again.
Press slightly and turn control knob counterclockwise 4to PILOT position;
depress control knob and light pilot by repeatedly pressing the sparker. Venting of
air may take place prior to flow of pilot gases. Once flame is established, hold knob
depressed for approximately 60 seconds.
MANUAL VALVE START-UP PROCEDURE
1.
2.
3.
4.
5.
6.
Turn control knob to the desired comfort level between the HIGH and the LOW
range. This control incorporates a temperature sensor near the unit. Once set to a
certain setting the flame will automatically modulate from “high” then to “low” and if
need to “off” and back again to keep a constant room temperature. You will need
to experiment to find the “right” setting.
7.
SHUT-DOWN PROCEDURE TO PILOT FLAME
To turn off the main burner only. Press and turn the knob clockwise 3 to PILOT
position.
Press and turn the knob clockwise 3to the OFF position.
COMPLETE SHUT-DOWN PROCEDURE
Sparker
Control Knob
Control indicator