p7
4.4.2 Display programming
Entering of the decimal
point location
* The changing of this param-
eter requires re-programming all
parameters related to the relays
and the analog ouptut, the bar-
graph as well as all following dis-
play parameters:
SPxx, hystx, do.diS, Fo.diS d.bArG,
F.bArG, d.diSP, FdiSP, bxx, Cut.oF
⇒ The instrument will
automatically resume
measure with the
previous configuration
if no key is pressed dur-
ing 1min.
«
04.00
«
dO.diS
Out.MA
Out.U
diSPL.
-.---
«
d.diSP
«
0000
«
F.diSP
«
5000
«
b01
Entering of the input down
scale “d.in” diplay from
-9999 to +99999
Analog output down scale
Analog output full scale
entering, display corresponding to the output down scale
entering, display corresponding to the output full scale
Entering of the input full
scale “F.in” display from
-9999 to +99999
Entering of the lineari-
sation points data from
-9999 to +99999
Setting in display points of
the same number of ordi-
nates “bxx” and abscisses
“Axx”
Setting in display
points
entering of the
cut-off from -9999
to +99999
according to options
according to options
IntEG : entering of the coefficient from 0 to 10
Integration indice
if integ ≠
0
«
2000
«
b18
«
Cut.oF
«
4000
«
YES
«
2000
Out.MA
Out.U
JbuS
tor
rELAY
SECU
«
IntEG.
«
0010
«
no
or
or
or
or
or
entering of the filtering action span in % of the measure range
0.5
0. 1
1
5
10
100
or
or
or
or
or
JbuS
tor
rELAY
SECU
or
or
or
See also output features
page 11
(4)
00.00 < x < 22.00 (mA)
00.00 < x < 11.00 (V)
(4)
(4)
Option analog output
«
«
Point
«
dISPL.
«
20.00
«
0000
«
2000
«
d.out
«
F.out
«
FO.diS
special linearisation
Out.MA
Out.U
or
M
Note
:
Press key to go on to next menu
Move through menus / choice
Upwards move / increase
Validation / vertical move
Downwards move /
decrease
Menu acess / exit
M
«
F.bAnd
⇒
The instrument will automatically resume measure with the previous con
-
figuration if no key is pressed during 1min.