17
To unmount indoor unit
Press the 2 ▲▲ marks on the lower part of the indoor
unit and unlatch the tabs. Then lift the indoor unit and
unmount. (Fig. 29)
3-9. Drain Hose
a) The drain hose should be slanted downward to the
outdoors. (Fig. 30)
b) Never form a trap in the course of the hose.
c) If the drain hose will run in the room, insulate the
hose with insulation* so that chilled condensation
will not damage furniture or floors. (Fig. 31)
* Foamed polyethylene or its equivalent is recom-
mended.
Do not supply power to the
unit or operate it until all tub-
ing and wiring to the outside
unit are completed.
must be used.