Outdoor Unit: AE752SCL
Compressor
Type
Compressor model
Nominal input W
Compressor oil…Amount cc.
Coil resistance (Ambient temp. 20°C)
Overload relay
Safety devices Type
Operating Temp. Open °C
Close °C
Run capacitor µF
VAC
Fan & Fan Motor
Type
Q'ty ……. Dia.
Fan motor model…Q'ty
No. Of poles…rpm (230 V, High)
Nominal output W
Coil resistance (Ambient temp. 25 °C )
Safety devices Type
Operating temp. Open °C
Close °C
Run capacitor µF
VAC
Heat Exch. Coil
Coil
Rows
Fin pitch mm
Face area
m
2
External Finish
DATA SUBJECT TO CHANGE WITHOUT NOTICE
2
1,5
0,51
Acrylic baked-on enamel finish
80 ± 15
2
440
Aluminium plate fin / Copper tube
BRN-WHT: 98.5
WHT-PNK: 201.0
Thermal protector
130 ± 5
1…. Ø 400
KFG6-51SB5P…1
6…900
40
50
370
Propeller
Internal
Thermal protector
N/A
N/A
1700
FV50S …670
C-R: 1,780
C-S: 2,175
Rotary (Hermetic)
5KS205EAA21
15