E
Power Supply:
230V / 1 / 50Hz *400 V / 3N / 50 Hz
1.Standard screwdriver
2.Phillips head screwdriver
3.Knife or wire stripper
4.Tape measure
5.Level
6.Sabre saw or key hole saw
7.Hacksaw
8. Core bits ø 5
19.Hammer
10.Drill
11.Tube cutter
12.Tube flaring tool
13.Torque wrench
14.Adjustable wrench
15.Reamer (for reburring)
16.Hex. key
Tools required for installation (not supplied)
Model Combinations
Combine indoor and outdoor units only as listed below.
Indoor Units Outdoor Units
AW726CL AE726SCL
AW726CLF
AW735CL AE735SCL
AW735CLF
FC735CL AE735SCL
AW752CL AE752SCL
AE752SCL3 *
FC752CL AE752SCL
AE752SCL3 *
AW764CL AE764SCL3 *
FC764CL AE764SCL3 *
Indoor Units
Outdoor Units
AW720HL AE720SH
AW726HL AE726SH
AW726HLF
AW735HL AE735SH
AW735HLF
AW752HL AE752SH
AW764HL AE764SH
AE764SH3 *
37.4255.043.01 11/2014
INSTALLATION INSTRUCTIONS
- Split system air conditioner -
P
GR
OPERATING LIMITS
L
Maximum conditions
Outdoor temperature : 43°C D.B.
Room temperature : 32°C D.B. / 23°C W.B.
L
Minimum conditions
Outdoor temperature : –15°C D.B.
Room temperature : 19°C D.B. / 14°C W.B.
OPERATING LIMITS
L
Cooling Maximum conditions
Outdoor temperature : 43°C D.B.
Room temperature : 32°C D.B. / 23°C W.B.
L
Cooling Minimum conditions
Outdoor temperature : 19°C D.B.
Room temperature : 19°C D.B. / 14°C W.B.
L
Heating Maximum conditions
Outdoor temperature : 24°C D.B. / 18°C W.B.
Room temperature : 27°C D.B.
L
Heating Minimum conditions
Outdoor temperature : –8°C D.B. / –9°C W.B.
COOLING Models
HEAT PUMP Models
COOLING Models
HEAT PUMP Models
REGULATION (EU) No. 517/2014 - F-GAS
The unit contains R410A, a fluorinated greenhouse gas with
a global warming potential (GWP) of 2087.50. Do not
release R410A into the atmosphere.
DECLARATION OF CONFORMITY
This product is marked as it satisfies Directives:
Low voltage no. 2006/95/EC.
(Standard: EN60335-2-40:2003 (incl. Corr.:2006) + A11:2004 + A12:2005 + A13:2012
+ A1:2006 + A2:2009 con EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 + A13:2008 + A14:2010 +
A15:2011).
Electromagnetic compatibility no. 2004/108/EC, 92/31 EEC and 93/68 EEC.
(Standard: EN55014-1 (2006) + A1(2009)
+ A2(2011), EN 55014-2 (1997) + A1(2001) + A2 (2008), EN 61000-3-2 (2006) + A1(2009) + A2(2009),
EN 61000-3-3 (2008)
RoHS2 no.2011/65/EU.
Regulation (EU) no. 206/2012, of 6 march 2012, concerning the specifications for ecodesign requirements of air
conditioners and fans.
Regulation (EU) no. 626/2011, of 4 may 2011, concerning the labeling indicating the energy consumption of air
conditioners.
This declaration will become void in case of misuse and/or non observance though partial of manufacturer's installation
and/or operating instructions.

Other manuals for Argo AE752SCL

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Argo AE752SCL and is the answer not in the manual?

Argo AE752SCL Specifications

General IconGeneral
BrandArgo
ModelAE752SCL
CategoryAir Conditioner
LanguageEnglish

Related product manuals