EasyManuals Logo

Argo AE752SCL User Manual

Argo AE752SCL
51 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #35 background imageLoading...
Page #35 background image
5-2 Cooling Capacity
OUTDOOR UNIT: AE726SCL
INDOOR UNIT: AW726CL
220 - 240V ~ 50Hz
RATING CAPACITY 2,70 kW moisture removal 0,8 l/h
COMP. POWER INPUT 0,68 kW max comp input 0,79 kW
AIR FLOW RATE 450 m³/h
EVAPORATOR
ENT.TEMP. °C
W.B. D.B. 20 25 30 35 40 43
TC 2,73 2,56 2,48 2,37 2,22 2,05
CM 0,54 0,57 0,60 0,64 0,67 0,71
21 SHC 1,89 1,75 1,72 1,66 1,59 1,51
23 SHC 2,14 1,99 1,95 1,89 1,82 1,74
15 25 SHC 2,37 2,22 2,17 2,11 2,04 1,96
27 SHC 2,62 2,45 2,40 2,34 2,22 2,05
29 SHC 2,73 2,56 2,48 2,37 2,22 2,05
31 SHC 2,73 2,56 2,48 2,37 2,22 2,05
TC 2,92 2,77 2,66 2,54 2,38 2,20
CM 0,56 0,59 0,63 0,66 0,69 0,73
21 SHC 1,63 1,53 1,49 1,43 1,36 1,27
23 SHC 1,88 1,76 1,71 1,66 1,58 1,50
17 25 SHC 2,12 2,00 1,94 1,88 1,81 1,73
27 SHC 2,37 2,23 0,74 2,11 2,04 1,95
29 SHC 2,62 2,46 2,39 2,34 2,27 2,18
31 SHC 2,85 2,69 2,62 2,54 2,38 2,20
TC 3,11 2,93 2,84 2,70 2,54 2,34
CM 0,58 0,61 0,65 0,68 0,71 0,75
21 SHC 1,37 1,29 1,24 1,19 1,12 1,03
23 SHC 1,62 1,51 1,47 1,41 1,34 1,26
19 25 SHC 1,86 1,73 1,70 1,64 1,57 1,49
27 SHC 2,10 1,95 1,93 2,14 1,80 1,71
29 SHC 2,34 2,17 2,15 2,09 2,03 1,94
31 SHC 2,59 2,40 2,38 2,32 2,25 2,17
TC 3,27 3,11 3,01 2,86 2,69 2,48
CM 0,58 0,62 0,66 0,69 0,73 0,77
23 SHC 1,34 1,27 1,23 1,17 1,10 1,02
21 25 SHC 1,59 1,49 1,45 1,40 1,33 1,24
27 SHC 1,83 1,71 1,68 1,62 1,56 1,47
29 SHC 2,08 1,93 1,90 1,85 1,78 1,70
31 SHC 2,31 2,16 2,13 2,07 2,01 1,93
TC 3,48 3,29 3,18 3,01 2,81 2,62
CM 0,59 0,63 0,67 0,71 0,75 0,79
23 25 SHC 1,31 1,23 1,19 1,13 1,06 0,99
27 SHC 1,55 1,44 1,41 1,35 1,28 1,21
29 SHC 1,80 1,66 1,64 1,58 1,51 1,44
31 SHC 2,05 1,90 1,87 1,80 1,73 1,67
TOTAL COOLING CAPACITY kW
SHC: SENSIBLE HEAT CAPACITY kW
CM: COMPRESSOR INPUT kW
RATING CONDITIONS
Cooling: Indoor air temperature 27°C D.B. / 19°C W.B.
Outdoor air temperature 35°C D.B. / 24°C W.B.
NOTE: Data referred to AW726CL
CONDENSER
OUTDOOR AMBIENT TEMP. °C
35

Other manuals for Argo AE752SCL

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Argo AE752SCL and is the answer not in the manual?

Argo AE752SCL Specifications

General IconGeneral
BrandArgo
ModelAE752SCL
CategoryAir Conditioner
LanguageEnglish

Related product manuals