2-3 Other Component Specifications
Thermostat
(
fan speed control
)
Switching temperature °C
Coil resistance
(
at 20°C
)
Rela
y
H62S
Contact rating 5 A - 220 V
Coil supply VAC 230
Coil resistance (20 °C) k 17,2 ± 10%
Power rela
y
(
compressor
)
(
PR
)
FINDER 65.31
Contact rating 30 A - 250 V
Coil supply 230 V ~ 50 Hz
Coil resistance (20 °C) 7250 ± 10%
Ne
g
ative Phase Rela
y
Type
Rating
Contact Rating
Operation
Fan Speed Controller
Type
Factory setting
Adjustable range
16 to 39bar
RGE-Z1L6-7DS
CISE131-V
AC 380 V, 3-PHASE 50 Hz
AC 250 V , 8 A
Positive phase: ON
Negative phase: OFF
HIGH…LOW 28,5°C ± 1
LOW…HIGH 31°C ± 1
YTB-S383
30bar
21