63
V 09/22
after it is shut down
The air conditioner
stops running after it
starts up for a while
May have reached the setting temperature.→ It is a normal function
phenomenon.
May be at a defrosting state. It will automatically restore and run again after
defrosting.
Shutdown Timer may be set. → If you continue to use, please turn it on again.
The wind blows out,
but the cooling/
heating effect is
not good
Excessive accumulation of dust on filter, blocking at air inlet and outlet, and the
excessively small angle of the louver blades all will affect the cooling and heating
effect.→ Please clean the filter, remove the obstacles at the air inlet and
outlet and regulate the angle of the louver blades.
Poor cooling and heating effect caused by doors and windows opening, and
unclosed exhaust fan.→ Please close the doors, windows, the exhaust fan,
etc.
Mode setting is incorrect, and the temperature and wind speed settings are not
appropriate.→ Please re-
select the mode, and set the appropriate
temperature and wind speed.
The indoor unit
blows out odor
The air conditioner itself does not have undesirable odor. If there is odor, it may
be due to accumulation of the odor in the environment.→ Clean the air filter or
activate the cleaning function.
There is sound of
running water
during the running
of air conditioner
When the air conditioner is started up or stopped, or the compressor is started up
or stopped during the running, sometimes the "hissing" sound of running water
can be heard. This is the sound of the flow of the refrigerant, not a
malfunction.
A slight "click" sound
is heard at the of
start-up or shut-down
Due to temperature changes, panel and other parts will swell, causing the sound
of friction. → This is normal, not a fault.
The indoor unit
makes abnormal
sound
The sound of fan or compressor relay switched on or off. When the defrosting is
started or stop running, it will create sound.→ That is due to the refrigerant
flows to reverse direction. They are not malfunctions.
Too much dust accumulation on the air filter of the indoor unit may result in
fluctuation of the sound. → Clean the air filters in time.
Too much air noise when "Strong wind" is turned on. This is normal, if feeling
uncomfortable, please deactivate the "Strong wind" function.
There are water
drops over the
surface of the
indoor unit
When ambient humidity is high, water drops will be accumulated around the air
outlet or the panel, etc. → This is a normal physics phenomenon.
Prolonged cooling run in open space produces water drops.Close the doors
and windows.
Too small opening angle of the louver blades may also result in water drops at the
air inlet. Increase the angle of the louver blades.
During the cooling
When the indoor temperature and humidity are high, it happens sometimes.
This is because the indoor air is cooled rapidly. After it runs for some time,