Specific information regarding appliances with R290 refrigerant gas
● Thoroughly read all of the warnings.
● When defrosting and cleaning the appliance, do not use any tools other than those recommended by the manufacturing
company.
● The appliance must be placed in an area without any continuous sources of ignition (for example: open flames, gas or
electrical appliances in operation).
● Do not puncture and do not burn.
● Refrigerant gases can be odourless.
● The appliance must be installed, used and stored in an area that is greater than 13 m
2
.
● R290 is a refrigerant gas that complies with the European directives on the environment. Do not puncture any part of the
refrigerant circuit.
● If the appliance is installed, operated or stored in a non-ventilated area, the room must be designed to prevent the
accumulation of refrigerant leaks resulting in a risk of fire or explosion due to ignition of the refrigerant caused by electric
heaters, stoves, or other sources of ignition.
● The appliance must be stored in such a way as to prevent mechanical failure.
● Individuals who operate or work on the refrigerant circuit must have the appropriate certification issued by an accredited
organization that ensures competence in handling refrigerants according to a specific evaluation recognized by associations in
the industry.
● Repairs must be performed based on the recommendations from the manufacturing company.
● Maintenance and repairs that require the assistance of other qualified personnel must be performed under the supervision of
an individual specified in the use of flammable refrigerants.
● Do not use means to accelerate the defrosting process or to clean, other than those recommended by the manufacturer.
● The appliance shall be stored in a room without continuously operating open flames (for example an operating gas appliance)
or other potential ignition sources (for example an operating electric heater, hot surfaces).
● All the work men who are engaging in the refrigeration system should bear the valid certification awarded by the authoritative
organization and the qualification for dealing with the refrigeration system recognized by this industry. If it needs other
technician to maintain and repair the appliance, they should be supervised by the person who bears the qualification for using
the flammable refrigerant.
● It can only be repaired by the method suggested by the equipment’s manufacturer.
● Do not pierce or burn.
● Be aware that the refrigerants may not contain an odour.
● Compliance with national gas regulations shall be observed.
● Keep ventilation openings clear of obstruction.
● The appliance shall be stored so as to prevent mechanical damage from occurring.
● A warning that the appliance shall be stored in a well-ventilated area where the room size corresponds to the room area as
specified for operation.
● Any person who is involved with working on or breaking into a refrigerant circuit should hold a current valid certificate from an
industry-accredited assessment authority, which authorizes their competence to handle refrigerants safely in accordance with
an industry recognized assessment specification.
● Servicing shall only be performed as recommended by the equipment manufacturer.
● Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under the supervision of the
person competent in the use of flammable refrigerants.