Service Manual
NEW ARISTON 60 cm PLATFORM
Edition
2006.06.15
Language
English
OPERATING LOGIC
2.6 STATIC APPLIANCES:
To introduce this technology in static appliances,
the following thermodynamic changes had to be
made: There are two solenoid valves instead of
one, physically positioned in “series” (cascade
connection), and three capillary tubes as opposed
to two; all electronically controlled as follows:
E.V.1-ON / E.V.2-Off (Capillary 1):
The gas is sent first to the fridge evaporator and
then to the freezer evaporator, as in traditional
models.
E.V.1-Off / E.V.2-Off (Capillary 2):
Here the gas is sent only to the freezer
compartment (not to the CCZ).
E.V.1-Off / E.V.2-On (Capillary 3):
In this case, the gas is sent first to the variable
temperature compartment and then to the freezer
compartment.
EV1
EV2
EV1
EV2
EV1
EV2
2 flags
1 flag
EV1
EV2
EV1
EV2
2 flags
1 flag
Capillary 3: TVZ+Fz
Capillary 2: Fz
Capillary 1: Fr+Fz
Gas in