WIRING DIAGRAMS
4.2 FULL WIRING DIAGRAM
Legend
AC Power supply
CO Compressor
PT Starter relay
C Running condenser (where fitted)
RH Klixon thermoprotector
E1 Solenoid valve
VZ NF freezer fan
R1, R2 Defrosting element
T1, T2 Thermo fuse
IF Fridge door button/magnetic reed
LR Fridge light
VR AIR fridge fan
LZ Freezer light
E2 Variable temperature compartment
solenoid valve
VA Vacuum switch (no measurable signal)
D1 Variable temperature compartment
damper on/off switch (J7 pin 1-3 power
supply 100V, pin 4-5 open/close reed limit
switch)
PV Vacuum pump
D2 Stepper damper (12V signal not
measurable)
S Serial line
UI Interface card with microprocessor
(J13 pin 3-4 power supply 12V, with ref.
to 220V do not touch the powered card)
S1 Evaporator probe (fridge for static
models, freezer for NF)
S2 Fridge air probe
S3 Freezer air probe
S4 Variable temperature compartment air
probe
4
31
2
413
5
5
4
4
3
21
21
4
3
2
1
1
2
3
4
54
3
2
1
3
2
1
4
654
3
21
6
543
2
1
c
m
s
3
2
1
2
1
6
7
8
3
4
1
5
331
C
J1
J2J8
J5J9 J10 J7
J12
J13 J3 J4J11
J6
AC
CO
PT
RH
E1
VZ
R1
R2
T2
T1
IF
LR
VR
LZ
E2
VA
S4
S1
S2
S3
D2
PV
S
D1
UI