Service Manual
NEW ARISTON 60 cm PLATFORM
Edition
2006.06.15
Language
English
A
SSISTANCE
FAULT CORRECTIVE ACTIONSCAUSE
- Check for water leaks that may affect connector J1 causing the relative contacts to
short;
- Check motor terminal board (possible problems due to incorrect connection which may
cause short-circuits);
- Renew motor;
- Renew PCB.
- Check effi ciency of contacts on connector J1 on the PCB;
- Check on wiring connector J1 between pins 3 and 2 for an impedance value that is
compatible with the value given in the specifi c table.
- Check that the compressor is not stopped due to overtemperature conditions (thermal
cutout open)
- Renew motor;
- Renew PCB.
- Renew PCB.
- Check effi ciency of contacts on connector J6 on the PCB;
- Check impedance on wiring connector J6 between pins 2 and 1 checking that the value
is compatible with the value given in the relevant table;
- Check correct connection of the freezer fan on the freezer compartment wiring junction
box;
- Renew freezer fan unit;
- Renew PCB.
- Check effi ciency of J3 connector contacts
on PCB;
- Check effi ciency of connection of electronic damper at foam protected connector
behind multifl ow;
- Renew electronic damper;
- Renew PCB.
- Check effi ciency of contacts on connector J6 on the PCB;
- Check condition by checking for impedance on wiring connector J6 pins 3 and 4;
- Check connections of the defrost heating elements and possible short circuits on the
freezer compartment wiring junction box;
- Renew heating element.
- Renew PCB
- Check effi ciency of contacts on connector J6 on the PCB;
- Check for continuity of the defrost heating element on pins 3 and 4 of connector J6,
ensuring that the impedance value read is compatible with the value given in the relevant
table;
- Check for correct connection of the defrost heating element and the drip tray heating
element on the freezer compartment wiring junction box;
- Check the correct impedance value on the defrost heating element across the heating
element terminals;
- Check that the fuses have not blown;
- Renew defrost heating element;
- Renew PCB.
- Check
effi ciency of contacts on connector J8 on the PCB;
- Check for impedance on wiring connector J8 pins 1 and 2 and ensure that the value
is compatible with the value given in the relevant table;
- Check correct switching of the solenoid valve With the compressor running, check that
the solenoid valve switches when the refrigerator compartment is set to OFF.
- Renew solenoid valve;
- Renew PCB.
- In the case of a production PCB, renew PCB and EEPROM;
- In the case of replacement PCB and EEPROM, check correct insertion of EEPROM in
PCB socket.
F1
Compressor relay sticking
Compressor relay open
Faulty power board
F3
F2
F4
Freezer fan unit does not run
F5
Electronic damper does not
close/open
F6
Triac driving defrost heating ele-
ment short-circuit
F7
No power draw of defrost heat-
ing element
F8
Incorrect switching of solenoid
valve
F9
File setup error (EEPROM not
programmed or faulty)