EN
30
Service Manual
NEW ARISTON 60 cm PLATFORM
Edition
2006.06.15
Language
English
A
SSISTANCE
FAULT
CORRECTIVE ACTIONS
CAUSE
- Check effi ciency of contacts on connector J11 on the PCB;
- Check NTC probe, ensuring that the impedance value read on pins 1 and 2 of
wiring connector J11 is compatible with the values in the temperature-imped-
ance correlation table (also heat the probe by holding it with your hand where
possible and checking the change in the impedance value);
- Renew main PCB.
- Check effi ciency of contacts on connector J11 on the PCB;
- Check NTC probe, ensuring that the impedance value read on pins 5 and 6 of
wiring connector J11 is compatible with the values in the temperature-imped-
ance correlation table (also heat the probe by holding it with your hand where
possible and checking the change in the impedance value);
- Renew main PCB.
- Check effi ciency of contacts on connector J11 on the PCB;
- Check NTC probe, ensuring that the impedance value read on pins 1 and 2 of
wiring connector J11 is compatible with the values in the temperature-imped-
ance correlation table (also heat the probe by holding it with your hand where
possible and check
ing the change in the impedance value);
- Renew main PCB.
- Check effi ciency of contacts on connector J12 on the PCB;
- Check NTC probe, ensuring that the impedance value read on pins 3 and 4 of
wiring connector J11 is compatible with the values in the temperature-imped-
ance correlation table (also heat the probe by holding it with your hand where
possible and checking the change in the impedance value);
- Renew main PCB.
- Renew Touch display PCB
- Renew Touch display PCB
- Renew Touch display PCB
- Renew Touch display PCB
- Renew Touch display PCB
- Renew Touch display PCB
- Renew Touch display PCB
- Renew Touch display PCB
F28
Display PCB does not work
F23
FRIDGE Evaporator NTC probe
open / short-circuit
F24
FREEZER Air NTC probe open /
short-circuit
F25
FREEZER Evaporator NTC probe
open / short-circuit
F26
CCZ Air NTC probe open / short-
circuit
F40
“ON/OFF ” button does not work
F41
“I Care” button does not work
F42
“Holiday” button does not work
F43
“ICE PARTY” button
F44
“Ever Fresh” button
F45
“Super Freeze” button
F46
“Super Cool” button
- Renew Touch display PCB
- Renew Touch display PCB
- Renew Touch display PCB
- Renew Touch display PCB
- Renew Touch display PCB
- Renew Touch display PCB
F47
“Alarm” button
F49
FRIDGE “+” button
F50
FRIDGE “-” button
F51
CCZ button
F52
FREEZER “+” button
F53