A
SSISTANCE
FAULT
CORRECTIVE ACTIONS
CAUSE
- Check effi ciency of contacts on connector J11 on the PCB;
- Check NTC probe, ensuring that the impedance value read on pins 1 and 2 of
wiring connector J11 is compatible with the values in the temperature-imped-
ance correlation table (also heat the probe by holding it with your hand where
possible and checking the change in the impedance value);
- Renew main PCB.
- Check effi ciency of contacts on connector J11 on the PCB;
- Check NTC probe, ensuring that the impedance value read on pins 5 and 6 of
wiring connector J11 is compatible with the values in the temperature-imped-
ance correlation table (also heat the probe by holding it with your hand where
possible and checking the change in the impedance value);
- Renew main PCB.
- Check effi ciency of contacts on connector J11 on the PCB;
- Check NTC probe, ensuring that the impedance value read on pins 1 and 2 of
wiring connector J11 is compatible with the values in the temperature-imped-
ance correlation table (also heat the probe by holding it with your hand where
possible and check
ing the change in the impedance value);
- Renew main PCB.
- Check effi ciency of contacts on connector J12 on the PCB;
- Check NTC probe, ensuring that the impedance value read on pins 3 and 4 of
wiring connector J11 is compatible with the values in the temperature-imped-
ance correlation table (also heat the probe by holding it with your hand where
possible and checking the change in the impedance value);
- Renew main PCB.
- Renew Touch display PCB
- Renew Touch display PCB
- Renew Touch display PCB
- Renew Touch display PCB
- Renew Touch display PCB
- Renew Touch display PCB
- Renew Touch display PCB
- Renew Touch display PCB
F28
Display PCB does not work
F23
FRIDGE Evaporator NTC probe
open / short-circuit
F24
FREEZER Air NTC probe open /
short-circuit
F25
FREEZER Evaporator NTC probe
open / short-circuit
F26
CCZ Air NTC probe open / short-
circuit
F40
“ON/OFF button does not work
F41
I Care button does not work
F42
Holiday button does not work
F43
ICE PARTY button
F44
Ever Fresh button
F45
“Super Freeze button
F46
“Super Cool button
- Renew Touch display PCB
- Renew Touch display PCB
- Renew Touch display PCB
- Renew Touch display PCB
- Renew Touch display PCB
- Renew Touch display PCB
F47
Alarm button
F49
FRIDGE + button
F50
FRIDGE - button
F51
CCZ button
F52
FREEZER + button
F53
FREEZER - button