12
GB
RECEPTION TEST
To check the correct communication be-
tween the receiver and transmitter, power
the timer-thermostat using the batteries
provided with the kit, as described in the
relative instruction manual.
Keep the timer-thermostat at least 2-3
metres away from the receiver and per-
form the following procedure:
- Press button .
- Press buttons “
“ together
with the PROGRAM “ “ button for
roughly 3 seconds. The display will vis-
ualise ”TRANSMISSION TEST’ and will
send the test signal to the receiver.
- The green LED on the receiver will start
fl ashing every 5 seconds for maximum
10 minutes. (During these 10 minutes
the receiver will not send any signal to
the boiler).
- Find a suitable zone in which to posi-
tion the timer-thermostat, while veri-
fying that the signal transmission is
not interrupted (green LED fl ashing).
- Press the
button to exit the TEST
mode.
NOTE:
If the red LED fl ashes on the receiver, the
transmission signal is inadequate.
Perform the receiver-transmitter recogni-
tion procedure.
LED CAUSE
GREEN fl ashing recognition of receiver-transmitter transmission
GREEN on reception of transmitter signal
GREEN off
receiver ready for normal operation
RED fl ashing receiver in re-connection mode
RED on communication between receiver and transmitter interrupted
RED off
receiver ready for normal operation
RED LED
BUTTON
GREEN LED