SETTINGS - ADJUSTMENT - PROBLEM IDENTIFICATION MENUS
803
Boiler Life Time (h x 10)
804
Time of fan ON (h x 10)
805
Number of fan cycles (n x10)
806
Number of fl ame detection in CH (n x10)
807
Number of fl ame detection in DHW (n x10)
81
BOILER STATISTICS-2
81 0Number of hours burner operating in heater mode (xxh/10)
81 1 Number of hours burner operating in hot water mode (xxh/10)
81 2 Number of fl ame separations (nr/10)
81 3 Number of ignition cycles (nr/10)
81 4 Average length of heating request (minutes)
8 2 BOILER
821 Fan Status 0 = OFF
1 = ON
822Fan speed (x100) rpm
824Diverter valve position 0 = D.H.W.
1 = Central Heating
825D.H.W. Flow Rate (l/min)
827 Modulating Pump (%)
828Gas Power (kW)
8 3 BOILER TEMPERTURE
831 Heating fl ow temperature (in °C)
832Heating backfl ow temperature (in °C)
8 4 SOLAR & STORAGE
842Solar appliance water input temperature activated only with the solar kit
connected
8 5 SERVICE
850Months to next maintenance from 0 to 60 (month) 24
If setted the boiler will display that is time to call the installer for maintenance
851 Enable Maintenance advice 0 = OFF
1 = ON
0
852 Maintenance Warning Reset Reset? OK= Yes Esc = No
to erase the advice for maintenance
853 2nd Heat Exchanger Clogging State 0 = DHW Exchanger OK
1 = Partially Clogged
2 = Very Clogged Please
Replace
854 PCB hardware version
855 PCB software version
8 6 ERROR LIST
86010 last errors from ERROR 0 to ERROR 9
This parameter allows the last 10 boiler errors fl agged to be displayed, indicating the day, month and year.
When the parameter is accessed, the errors are displayed listed from ERROR 0 to ERROR 9.
For each error, the following sequence is displayed:
E00 - error number
108 - error code
861 Error list reset Reset
OK = yes
ESC = no
menu
sub-menu
Parameter
Description value
default setting