EasyManua.ls Logo

Ariston E-Combi One LPG - Page 61

Ariston E-Combi One LPG
76 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
/ 61
MAINTENANCE GUIDE
Remove the three screws to free the fan.
2
Remove the three nuts.
Verify and replace the gasket if it’s damaged or showing
signs of deterioration
3
Legend:
1 - Fan
2 - Venturi
3 - Gasket
Fan & mixer venturi according to the model
Power Fan Venturi diameter
24 kW EBM 118 85W Ø 16,1
30 kW EBM 118 85W Ø 18,7
1
2
1
3
4.4 Gas Valve
Tools
TIME 15 min
Remove the two screws under the boiler and disconnect the
gas pipe on the top of the gas valve
1
Remove the gas valve
2
Legend:
1 - Gas valve
2 - Solenoids
3 - Throttle adjustment
4 - Offset adjustment
5 - Inlet test nipple

Table of Contents