EasyManuals Logo

Ariston microGENUS 23 MFFI Servicing Instructions

Ariston microGENUS 23 MFFI
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #22 background imageLoading...
Page #22 background image
22
B063
IS
THERE STILL
A PROBLEM?
NORMAL
OPERATION
NO
YES
FAULTS
POSSIBILE CAUSES
1
2
3
4
5
6
7
8
9
D
Drawing D.H.W:
When you turn on a tap
burner switches off
Drawing D.H.W:
radiators heat up in summer mode
Drawing D.H.W:
insufficient hot water
temperature
Drawing D.H.W:
noisy operation
Decrease/increase
heating circuit pressure
Repeated shutdowns
Repeated intervention of safety thermostat
When cold water tap turned off, the boiler
ignites
Insufficient radiator temperature
- air in secondary heat exchanger
- faulty main circuit flow switch
- faulty D.H.W. flow switch
- faulty 3-way valve
- check C.H./D.H.W. temperature probes
- check gas pressures
- check water flow rate
- check secondary heat exchanger
- primary heat exchanger faulty or
lime-scale deposits
- low heating system water pressure
- check gas pressures
-
check C.H./D.H.W. temperature probes
- check for leaks on the heating circuit
- faulty filling-loop
- faulty secondary heat exchanger
- expansion vessel faulty
- faulty detection electrodes
- check gas settings
- check flame detection electric circuit
- C.H./D.H.W. temperature probes open circuit
- overheat thermostat not calibrated correctly
- air in primary water circuit
- drop in pressure in the water mains, with
consequent water hammer
- check C.H. temperature probe
- check by-pass
- check gas pressures
FC004Ae

Other manuals for Ariston microGENUS 23 MFFI

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ariston microGENUS 23 MFFI and is the answer not in the manual?

Ariston microGENUS 23 MFFI Specifications

General IconGeneral
BrandAriston
ModelmicroGENUS 23 MFFI
CategoryBoiler
LanguageEnglish

Related product manuals