23
B063
3. ELECTRICAL
DIAGRAMS
LEGEND:
A = Time Clock Connector
B = Central Heating Selection (Winter) and
Temperature Adjustment
C = Connector for Total Check System
D = Domestic Hot Water Temperature Adjustment
E = Soft-light Adjustment
F = Maximum Heating Adjustment
G = On/Off Switch
H = On/Off L.E.D.
I = Fume Sensor L.E.D.
J = Ignition Failure (Lockout) L.E.D.
K = Low System Water Level/Lack of Circulation L.E.D.
L = Reset Button
M = Economy/Comfort Selector
N = Overheat L.E.D.
O = Temperature L.E.D.s
P = Transformer
Q = Circulation Pump Relay
R = Fan Relay
S = Gas Valve Relay
T = Motorised Diverter Valve Relay
V = Spark Generator
U = Anti-cycling Device Adjustment for Heating
A01 = Circulation Pump
A02 = Fan
A03 = Spark Generator/Gas Valve Supply
A04 = Motorised Diverter Valve
A05 = Flame Detection Circuit
A06 = Detection Electrode
A07 = Main Circuit Temperature Probe
A08 = Domestic Hot Water Temperature Probe
A09 = Domestic Hot Water Flow Switch
A10 = Main Circuit Flow Switch
A11 = Modulator
A12 = Air Pressure Switch
A13 = Safety Thermostat
A14 = External (Room) Thermostat
Colours:
Gry = Grey
Wh = White
Pnk = Pink
Brn = Brown
Bl = Blue
Blk = Black
Rd/Blk = Red/Black

Other manuals for Ariston microGENUS 23 MFFI

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ariston microGENUS 23 MFFI and is the answer not in the manual?

Ariston microGENUS 23 MFFI Specifications

General IconGeneral
BrandAriston
ModelmicroGENUS 23 MFFI
CategoryBoiler
LanguageEnglish

Related product manuals