OPERATION AND FUNCTIONS
INPUT Control Object
COMP ON/OFF
COMP
F-FAN
CONTENTS REMARKS
1) F-fan delay by comp. ON/OFF
F-fan is ON/OFF 1 minute after comp. is ON/OFF.
2) Fan Delay and Priority
R F AN
ON condition
0.5s ec .
ON
ON
ON
1.0s ec .
1.5s ec .
F FA N
C F AN
OF F
OF F
OF F
1 min.
1 min.
3-14. Delay Function of Electric Compartments