16 1X-F Series Operation Manual
Displaying local indications only
For control panels connected in a fire network and with repeater functionality, an
indication is activated if any control panel in the network being repeated has the
feature activated. For zone indications which are global in the fire network, it is
not required to repeat other control panels to show their zone indications.
Therefore all control panels display the local and remote information. If you need
to show only local status in a control panel:
Press the Enter button for at least 3 seconds.
A steady Networking Fault LED indicates network remote indications are
disabled momentarily.
Only local information is shown for 30 seconds. After this time, the
Networking Fault LED turns off and the control panel shows global (local and
remote) information according to its configuration.
Example 1
If you have a 16-zone conventional system with two 8-zone conventional control
panels where both panels repeat each other, and you need to identify which
panel has a supply fault you should press Enter for 3 seconds. The control panel
without the supply fault will turn off the supply fault indication.
Example 2
If you have a 16-zone conventional system with two 8-zone conventional control
panels which are not repeating each other, then one panel has a zone range of 1
to 8 and the other panel has a zone range of 8 to 15. Sharing zone 8 will allow
activating outputs of one control panel with events of zone 8 in the other panel.
If there is a defective device causing false alarms in zone 8 of panel 1, you can
disable it and keep some detection active (zone 8 of panel 2 operational). The
zone 8 yellow LED will activate in both panels. Afterwards, an alarm in zone 8 of
panel 2 will cause both panels to activate and the zone 8 red and yellow LEDs in
both panels will be active.
Pushing Enter for 3 seconds in panel 1 will cause the red LED indication of zone
8 to disappear, indicating that the control panel has zone 8 disabled. At this point,
you will know the alarm is from zone 8 of panel 2. You can confirm this by
pushing Enter for 3 seconds in panel 2. In this case, the yellow LED indication
disappears.

Other manuals for Aritech 1X-F Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Aritech 1X-F Series and is the answer not in the manual?

Aritech 1X-F Series Specifications

General IconGeneral
BrandAritech
Model1X-F Series
CategoryControl Panel
LanguageEnglish

Related product manuals