ARITERM AB ARITERM OY Installation and operating instruction • Version 2.0 • 12.04.2017 9/32
5P01781-A / 5P01781-B
WIRING DIAGRAM - Biomatic+ 40i
J10
J105 J101
32J4J42J
J102 J103 J104 J25 J6 J28 J27 J5
Convection cleaning
External auger
Burner auger
Fan 1
Fan2
Fan 3
PSU
Immersion heater
L
N
PE
Com
+12V
Com
+5V
A1A2
Contactor
SW. w. pump
SW. on/off SW. Imm. heater
Fuse w. pump
Main fuse
Relay
Thermostat
Cut out
Thermostat
LED R/G
Ignition element
L1 L2 L3 N PE
Yellow/green
Black
Filter
Black
Black
Black
Black
Black
Black
Black
Black
Black
Tap water pump
Black
Blue
Charge pump
Blue
Brown
Black
Brown
Black
Blue
White
Red
Blue
Blue
P1
Black
Brown
Black
J26
Red
Red
Red
Red
Red
Black
Brown
Boiler
Sensor
Flue gas
Sensor
Brown (2x)
Grey (2x)
Circulation pump
N L
Brown
Blue
Blue
Blue
Brown
Brown
Black
Black
Red
Red
Red
Black (2x)
Black
Brown
Red
Grey
Black
Yellow
Black (white)
White
Orange
Black (yellow)
Black (orange)
Flam
e sensor
Level
sensors
Black
Red
Grey
White
Blue
Brown
2
6
5
1
3
4
Oxygen sensor
Tank sensor (top)
Tank sensor (bottom)
Alarm relay
CRB (ESBUS communication)
Blue
Black
Yellow/green
Yellow/green
BM61021v1 140821
1
6
8
7
2
4
5
3
9
10
1
6
8
7
2
4
5
3
9
10
Black
Red
Grey
White
Blue
Brown
2
6
5
1
3
4
A
B
B
A

Related product manuals