DSTREAM-ST Getting Started Guide Document ID: 100892_1.0_07_en
Version 1.0
Troubleshooting
Next steps
You must perform a firmware update to restore full functionality.
To update the firmware to the latest version, see Update the DSTREAM-ST firmware.
5.3 Remotely restart a DSTREAM-ST unit
Describes how to remotely restart a DSTREAM-ST unit.
Remote restart is not supported by Arm Development Studio
Arm
®
Development Studio does not currently have a feature to remotely restart a DSTREAM-ST
unit, however, a workaround is available.
Workaround
To restart your DSTREAM-ST unit, update the firmware. At the end of a firmware update, the
DSTREAM-ST unit restarts.
To update the firmware of a DSTREAM-ST unit, either use:
The Arm Development Studio GUI. For instructions, see Update the DSTREAM-ST firmware.
The dbghw_batchupdater utility on the command line. For instructions, see the Updating
multiple debug hardware units topic in the Arm Development Studio User Guide.
5.4 Troubleshoot target connections
Your DSTREAM-ST unit is built for robust performance, but problems can arise when:
Incompatible hardware is used with software.
Hardware is not configured or connected correctly.
Other hardware-related issues.
Table 5-1: Target connection troubleshooting
Check List Things to check
Are you using the latest version of Arm
®
Development Studio?
Download and install the latest version of Arm Development Studio.
New functionality, bug-fixes, and support for new targets are
provided with every release of Arm Development Studio.
Are you using the latest firmware for your DSTREAM-ST unit. Use the Debug Hardware Firmware Installer view in Arm
Development Studio to update the firmware for your DSTREAM-ST
unit.
Are all the cables connected and seated properly in the correct
orientation.
Make sure all the cables are connected and seated properly.
Check that the stripe on the debug cable matches up with
pin-1 of the debug connector.
Does the pin-out of the target's debug connector match the pin-out
of your DSTREAM-ST unit?
Check the connection pin-out details of your connector.