15
INSTALLING FOAM WET FILTER
1. Verify that the power cord is disconnected from the outlet (Fig. 1).
2. Remove the power head and place in an upside-down position. Follow instructions to remove
the reusable cloth lter on page 14.
3. Carefully slide the foam wet filter over the filter cage making sure the cage is completely
covered (Fig. 2 & 3).
4. Place the power head onto the collection tank.
CLEANING FOAM WET FILTER
1.
With the removed power head in an upside-down position, carefully remove the foam wet lter (Fig. 4).
2. Use a mild soap and water solution to wash the foam wet lter and rinse with clean water (Fig. 5).
3. Allow the lter to air dry for 24 hours before installing onto the lter cage.
PROBLEM POSSIBLE CAUSE SOLUTION
The wet/dry vacuum will not
operate.
No power supply.
Check the power supply, cord,
breakers, and fuses.
Faulty power cord.
Unplug and check the power
cord. If damaged, have it
repaired by a professional.
Collection tank is full. Empty the collection tank.
Switch in the wrong position.
Press the ON ‘I’ button on the
power head.
The dust comes out from the
motor cover.
The reusable cloth lter is
missing or damaged.
Attach or replace the reusable
cloth lter.
Reduced eciency and motor/
speed vibration.
There are blockages in the
nozzle, hose, or the collection
tank inlets.
Unplug and check nozzle,
hose and collection tank inlets
for blockages.
The reusable cloth lter is
clogged by ne dust.
Take o the lter and clean it or
install a new reusable cloth lter.
TROUBLESHOOTING
INSTALLING & CLEANING FOAM WET FILTER
WARNING:TO REDUCE THE RISK OF ELECTRIC SHOCK, UNPLUG BEFORE
TROUBLESHOOTING.