Page 1 of 18Issue 1324507120-01
This is a safety alert symbol and should never be ignored. When you see this symbol on labels or in
manuals, be alert to the potential for personal injury or death.
NOTE: These instructions are intended as a general guide and do
not supersede national, state or local codes in any way.
These instructions must be left with the property owner.
The Clean Air Act of 1990 bans the intentional venting of
refrigerant (CFCs, HCFCs and HFCs) as of July 1, 1992.
Approved methods of recovery, recycling or reclaiming
must be followed. Fines and/or incarceration may be
levied for noncompliance.
CAUTION
Shipping and Packing List
Package 1 of 1 contains the following:
1- Assembledairhandlerunitforupoworhorizontalair
dischargeapplication(includesupowand horizontal
drain pans and pre-installed air lter).
Check equipment for shipping damage. If found, immediately
report damage to the last carrier. Check the unit rating plate
toconrmthatdeliveredunitmatchesorder.
TABLE OF CONTENTS
Shipping and Packing List .........................................................1
Unit Dimensions ........................................................................2
Requirements ............................................................................3
Installation Clearances ..............................................................3
Installation ..............................................................................4
Condensate Drain......................................................................7
Duct Systems and Filters...........................................................8
Connecting Refrigerant Lines ....................................................9
Sealing the Unit .........................................................................9
Electrical Connections .............................................................10
Airow-CoolingBlowerSpeed ...............................................12
Check - Out Procedures ..........................................................13
Operation 13
Maintenance ............................................................................14
Cabinet Insulation .................................................................... 14
Warranty 17
Product contains berglass wool.
Disturbing the insulation in this product during
installation, maintenance, or repair will expose you to
berglasswool.Breathingthismaycauselungcancer.
(Fiberglass wool is known to the State of California to
cause cancer.)
Fiberglass wool may also cause respiratory, skin, and
eye irritation.
To reduce exposure to this substance or for further
information, consult material safety data sheets
available from address shown below, or contact your
supervisor.
WARNING
INSTALLATION INSTRUCTIONS
BCE3M & BCS3M SERIES AIR HANDLER
These instructions must be read and understood completely before attempting installation.
0659373-80 Version B
ManufacturedBy
Advanced Distributor Products
A Lennox International, Inc. Company
1995 Air Industrial Park Road
Grenada, MS 38901
(P) 507120-01
*P507120-01*
Improper installation, adjustment, alteration, service
or maintenance can cause property damage, personal
injury or loss of life. Installation and service must
be performed by a licensed professional installer (or
equivalent), service agency or the gas supplier.
WARNING
Question and Answer IconNeed help?

Do you have a question about the Armstrong Air BCE3M 18 and is the answer not in the manual?

Armstrong Air BCE3M 18 Specifications

General IconGeneral
BrandArmstrong Air
ModelBCE3M 18
CategoryAir Handlers
LanguageEnglish

Related product manuals