507789-01 Issue 2007 Page 1 of 24
Save these instructions for future reference
This manual must be left with the homeowner for future reference.
This is a safety alert symbol and should never be ignored. When you see this symbol on labels or in
manuals, be alert to the potential for personal injury or death.
INSTALLATION INSTRUCTIONS
BCE5V Series Air Handler
(P) 507789-01
*P507789-01*
Manufactured By
Allied Air Enterprises LLC
A Lennox International, Inc. Company
215 Metropolitan Drive
West Columbia, SC 29170
Table of Contents
BCE5V Unit Dimensions – Upow – Inches (mm).......2
Shipping and Packing List ...........................................3
General ........................................................................3
Requirements ..............................................................3
Use of Air Handler During Construction.......................4
Installation Clearances ................................................4
Installation ...................................................................4
Condensate Drain........................................................7
Duct System and Filters .............................................9
Brazing Refrigerant Lines ............................................9
Sealing the Unit .........................................................11
Electrical Connections ...............................................12
BDC3 Blower Control ................................................16
Adjusting the Blower Speed ......................................16
Blower Performance ..................................................17
Checkout Procedures ................................................21
Professional Maintenance .........................................22
Homeowner Maintenance..........................................22
Repairing or Replacing Cabinet Insulation ................22
Improper installation, adjustment, alteration, service
or maintenance can cause property damage, personal
injury or loss of life. Installation and service must be
performed by a licensed professional HVAC installer or
equivalent, service agency, or the gas supplier.
WARNING
The Clean Air Act of 1990 bans the intentional venting
of refrigerant (CFCs, HCFCs and HFCs) as of July
1, 1992. Approved methods of recovery, recycling or
reclaiming must be followed. Fines and/or incarceration
may be levied for noncompliance.
IMPORTANT
As with any mechanical equipment, contact with sharp
sheet metal edges can result in personal injury. Take
care while handling this equipment and wear gloves
and protective clothing.
CAUTION
Question and Answer IconNeed help?

Do you have a question about the Armstrong Air BCE5V30MA4X and is the answer not in the manual?

Summary

Installation

Install Condensate Drain

Details on connecting primary and secondary drain lines, ensuring proper slope and trap installation.

Duct System and Filters

Brazing Refrigerant Lines

Sealing the Unit

Electrical Connections

BDC3 Blower Control

Adjusting the Blower Speed

Guide to setting blower speed using jumpers on the BDC3 control for specific CFM requirements.

Checkout Procedures

Pre-Start-Up Checks

Checklist of essential items to verify before starting the unit for the first time.

Professional Maintenance

Homeowner Maintenance

Check Electric Heat (If Used)

Armstrong Air BCE5V30MA4X Specifications

General IconGeneral
ModelBCE5V30MA4X
Phase1
Hertz60
Cabinet MaterialGalvanized Steel
TypeAir Handler
Cooling Capacity2.5 Ton
Voltage208/230V
Cabinet FinishPainted
Cabinet TypeFully Insulated
Filter TypeStandard