Armstrong 4382 ivs User Manual

Armstrong 4382 ivs
41 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
1
FILE NO: 94.82L
DATE: Aug. 24, 2009
SUPERSEDES: New
DATE: New
Series 4302 IVS Vertical In-Line Pumping Unit
with Integrated Controls
INSTALLATION AND OPERATING INSTRUCTIONS
Product shown with coupling guards removed
Question and Answer IconNeed help?

Do you have a question about the Armstrong 4382 ivs and is the answer not in the manual?

Armstrong 4382 ivs Specifications

General IconGeneral
Model4382 IVS
Power SourceElectric
Seal TypeMechanical Seal
Voltage230 V
Maximum Flow25 m³/h
Inlet/Outlet Size2 inches
Inlet Size2 inches
Outlet Size2 inches
Impeller MaterialStainless Steel
Weight15 kg

Summary

INSTALLATION AND OPERATING INSTRUCTIONS

1.0 UNCRATING

Instructions for safely removing and inspecting the pumping unit from its packaging.

2.0 INSTALLATION

Guidance on properly setting up the pumping unit for operation.

2.1 MECHANICAL INSTALLATION

Details on physical placement, mounting, and piping for the pump.

2.1.6 STARTING PUMP

Procedure for safely starting the pump after installation or service.

INTEGRATED CONTROLS

4.0 ELECTRICAL INSTALLATION

Instructions for safe and compliant electrical connections to the unit.

SAFETY, RISK OF DEATH

Critical safety warnings for working with the electrical system.

4.6 EARTHING AND IT MAINS

Requirements for earth connection and IT mains supply connections.

4.8.2 CONTROL TERMINALS

Detailed description of control terminal functions and their factory settings.

4.8.3 CONNECTION EXAMPLES

Common examples of pump control configurations and wiring.

4.9 CONTROL CONNECTIONS

Details on connecting external control signals and communication.

5.0 PROGRAMMING, MONITORING AND DIAGNOSTICS

5.1 GLCP FUNCTIONS AND OPERATION

Guide to using the Graphical Local Control Panel (GLCP) for operation.

5.1.3 CONTROL KEYS

Description and function of the control panel keys for navigation and operation.

5.4 PROGRAMMING

Guide to navigating and changing parameters using the Main Menu.

6.0 SENSORLESS OPERATION

6.1 DEFAULT OPERATING MODE - QUADRATIC PRESSURE CONTROL

Setting the pump to default quadratic pressure control mode.

6.2 CONSTANT PRESSURE CONTROL

Configuring the pump to maintain a constant system pressure.

6.3 PROPORTIONAL PRESSURE CONTROL

Setting up proportional pressure control for linear head reduction.

7.0 CONTROL USING EXTERNAL FEEDBACK (CLOSED LOOP CONTROL)

Using external feedback signals for closed-loop pump control.

8.0 WARNINGS AND ALARMS

Related product manuals