hang off the telephone after 20 seconds delay, and go back to waiting status£»
£¨2£©.When there are more than 1 D-IN instructions in the users program of SR:
A£®If all of the password protection of D-IN was selected, the voice module Will play
the No.01 message repeatedly, when the user enter the password, If the password
is wrong, the voice module will play the No.03 message, And then will play the
No.01 message repeatedly, if the entered password is correct, voice module will
play the No.02 message, and then play the preset alarm message which was set in
the D-IN for 3 times, when it finish to play the 3 times, the voice module will
stop playing any messages, and will hang off the telephone after 20 seconds
delay. And go back to waiting status.
B£® If there isnt any password protection for the D-IN instruction, the voice module
will play the alarm message which was preset in the D-IN by user for 3 times,
after 3 times playing, the voice module will stop playing any messages , and will
hang off the telephone after 20 seconds delay, and then go back to waiting
status£»
C£® If there is password protection for some D-IN instructions, and some D-IN
instructions havent password protection, then the voice module will play the
preset alarm messages that are preset in the D-IN instructions without password
protection. After playing all the alarm message which havent password
protection, the voice module will play the No.01 message, after the user enter the
password, if the entered password is wrong, the voice module will play the
No.03 message, and will continue to play the No.01 message£»if the entered
password is correct, the voice module will play the No.02 message, then the
voice module will play the alarm messages which preset in the D-IN instructions
with password protection, after playing all the alarm messages for all D-IN
instructions, the voice module will start to play all the alarm messages for 2
times, at last the voice module will stop playing any message, and hang off after
20 seconds delay, and go back to waiting status;
3. When the user dial the telephone number which is connected to the voice module,
and the D-IN instruction wasnt activated, then voice will play the No.04 message
to tell the user that there isnt any alarm.
4. When the user hear the voice module, if the user hang off the telephone, then the
voice module will hang off the telephone automatically after a few seconds delay
after playing the previous message.
Note£º
1. The No.01, No.02, No.03 and No.04 message are system message, and cannot be
played in D-IN instruction.
2. When this voice module is used, the related voice messages must be recorded first.
3. User must record the messages firstly, then can use the voice module No.01,
No.02, No.03 and No.04 message must be record before using the voice module
(Please refer the chapter VI to study Recording message of voice module)
4. Password input must be start as *.