plug-in two leads. Only one 13 amp lead per 13 amp extension lead. Plugging both of the Ninja’s
electrical leads into a double wall socket is permissible as along as each socket is 13 amp 3 Kw
rated.
2. Fill solution tank with clean water to required level. The heater will not operate until the float
switch is covered.
3. Switch on tank heater switch and dial thermostat to required temperature. The thermostat dial
will not turn passed the recommended top temperature for the pump i.e. 60°c or 70°c depending
on pump model. The thermostat will automatically turn off the heater at the temperature setting
selected and the red neon light will turn off. The heater switch will remain illuminated to indicate
that power to the heater is on. The heater will switch off automatically when the water level
drops to the minimum safe level. The heater will not operate with no water in the solution tank.
Internal V2 SteamMate (if fitted)
1. Plug-in Black Heater Lead to a 13 amp 240 Volt socket - ensure that it is on a RCD protected
circuit. Important: When using any electrical equipment at customer’s premises, you should
have a plug-in 13 amp RCD on each power lead. In the event of a fault, an unearthed or non-RCD
protected power supply can cause injury or death. Do not use an extension lead with double plug
ability, to plug-in two leads. Only one 13 amp lead per 13 amp extension lead. Plugging both of
the Ninja’s electrical leads into a double wall socket is permissible as along as each socket is 13
amp 3 Kw rated.
2. Always connect V2 Fully Sleeved or heat-protected solution hose and cleaning tools to the
machine before switching on the V2 SteamMate - the heat will increase the water pressure and
cause resistance when connecting the hose.
3. Set selected temperature on V2 SteamMate dial, this will give a temperature range of between
0°c to 110°c.
4. The V2 SteamMate will not operate until:
a. The solution tank is above the minimum level of water required to engage the float
switch.
b. The water pump is switched on.
The red neon will turn off when the temperature in the V2 SteamMate reaches the selected temperature.
Please note that the V2 SteamMate heater switch will remain illuminated to indicate the power is on (if
fitted with an illuminating switch).
Warning: The V2 SteamMate will produce very hot water under pressure and should only be used with
hoses and tools designed for high heat and pressure. Injury could result from using low pressure or low
heat-rated accessories. When venting or spraying always do so into a suitable container, or onto the item
being cleaned – never on people or animals. Green neon will indicate which system is operating on dual
heat models.
Water Pump & Vacuum System
1. Plug-in white mains Lead to a 13 amp 240 Volt socket - ensure that it is on a RCD protected
circuit. IMPORTANT – When using any electrical equipment at customer’s premises, you should
have a plug-in 13 amp RCD on each power lead. In the event of a fault, an unearthed or non-RCD
protected power supply can cause injury or death. Do not use an extension lead with double plug
ability, to plug-in two leads. Only one 13 amp lead per 13 amp extension lead. Plugging both of