Page 6 of 11
the Ninja’s electrical leads into a double wall socket is permissible as along as each socket is 13
amp 3 Kw rated.
2. Open flow control valve one turn anticlockwise, to allow free recirculation of water back to the
solution tank.
3. Connect suitably rated solution hose to machine and cleaning tool.
4. Switch on the green mains switch. This will automatically turn on the cooling fan system and
provide power to the switch panel, vacuumand pump systems.
5. Switch on the water pump and allow to run on recirculation whilst switching on vacuums.
6. Switch on vacuum motor No 2.
7. Switch on vacuum motor No 1.
8. Ensure Brass Pressure Control valve is turned fully clockwise to maximum (in direction of arrow).
9. Close Flow Control (by turning clockwise), to produce required flow-rate and pressure up to 400
psi.
10. Commence cleaning.
Emptying Soiled / Dirty Water from the Ninja
When the recovery tank is full a float ball shut off system will operate. When vacuum power is lost turn
off vacuum motor No 1 followed by No 2. Empty soiled water via the dump valve into a dedicated dirty
water bucket. Empty soiled water into a sewage sluice i.e. toilet or manhole. Do not contaminate rain
water drains. Refill solution tank using dedicated clean buckets and continue working.
Hot Solvent Extraction Cleaning
Fitted with an Adjustable 3 Kw Tank Heater
Warning: when solvent cleaning always follow safety procedures detailed on the solvent container, which
involves wearing suitable solvent protective mask & gloves.
1. Fill solution tank to above level of copper coil heat exchanger with water (preferably hot),
ensuring heater element low level float switch is covered. Plug white & black mains leads into
separate 13 amp sockets. Ensure thatelectrical supply is fitted with an RCD earth leakage trip.
When using any electrical equipment, switch on heater and dial up temperature to 60°C, located
on main switch panel.
2. Whilst the machine is heating water, connect solvent intake tube to rear of machine via brass
coupling. Hook solvent container cage to Ninja’s rear handle and place 5 Ltr container of solvent
cleaning fluid in cage. Place the other (open) end of the intake tube into the solvent container.
Ashbys Cleaning Equipment strongly recommends using an odour-free solvent such as Dry Clean
Extra PC6234 or Supreme Dry Clean PC4502. Using unsuitable solvents can be dangerous
because of toxicity and fire / explosion risk.
3. Connect solvent re-circulation hose to Ninja via double brass connections. The other end can be
connected to required solvent cleaning tool.
4. If the solvent system has been drained dry or contaminated by water, you can use the solvent
bleed hose to bleed the system. Connect the bleed hose to the female socket of the recirculation
hose and run pump until clean solvent is pumped through.