852072K-0301H
• Please read this entire manual before installation and use of
this appliance. Failure to follow these instructions could result
in property damage, bodily injury, or even death.
• Contact your local building or re ofcials about obtaining
permits, restrictions and installation inspection requirements in
your area.
• Save these instructions.
• If your heater is not properly installed, a house re may result.
For everyone’s safety, follow all Installation and Operating
Directions. Never use makeshift compromises during the
installation of this appliance. Contact your local building
or re ofcials about restrictions and installation inspection
requirements in your area. These Pellet Stove Room Heaters
have been designed for use in the US and Canada and are
suitable for mobile homes.
This unit is not intended to be used as
a primary source of heat.
U.S. Environmental Protection Agency
Certied to comply with 2015
particulate emissions standards.
United States Stove Company
227 Industrial Park Road
South Pittsburg, TN 37380
MODEL: AP5660L
Owner’s Operation and Instruction Manual
SAVE THESE INSTRUCTIONS
THIS MANUAL WILL HELP YOU TO OBTAIN EFFICIENT, DEPENDABLE SERVICE FROM THE HEATER, AND ENABLE YOU
TO ORDER REPAIR PARTS CORRECTLY. KEEP IN A SAFE PLACE FOR FUTURE REFERENCE.
Certied to ASTM E 1509, 2012, and Certied
to ULC S627, 2000, and(UM) 84-HUD

Other manuals for Ashley AP5660L

Questions and Answers

  • G
    Gary RandallSep 9, 2025
    How to troubleshoot Ashley AP5660L exhaust blower that does not operate normally?
    • B
      bradyrebeccaSep 10, 2025
      Check all wiring connections to the exhaust blower. If the connections are good, apply 120 volts directly to the exhaust blower. If the blower still does not run, replace it.
  • W
    wferrellSep 8, 2025
    What does it mean if the 200°F High-limit switch has tripped on my Ashley Wood stove?
    • P
      Patrick WilsonSep 9, 2025
      Reset the switch and try to determine the cause, which is often a faulty circulation fan. If the circulation fan isn't working, test it by applying 120 volts directly to it; if it still doesn't operate, replace the fan.
  • D
    Daniel ReyesSep 7, 2025
    Why does the Ashley Wood stove flame keep going out on 'LOW' setting?
    • M
      Matthew PhillipsSep 7, 2025
      Try increasing the heat level on the control panel using the HEAT button, as poorer quality pellets may need a higher setting. If it's already on heat level 1, adjust the fuel feeding rate slightly using the Auger Trim button. The heater might also need more air.
  • M
    Marie ChaneyAug 23, 2025
    What to do if Ashley Stove feeds pellets, but will not ignite?
    • R
      Rachel LiuAug 23, 2025
      If your Ashley Stove is feeding pellets but not igniting, try these steps: First, adjust the air damper closer to the side of the stove for startup, even completely closing it if needed. Check for any blockages in the igniter tube or its inlet. Ensure the burnpot is pushed completely to the rear of the firebox. Test the igniter element to see if it glows after two minutes of direct power. Finally, check if the control board is sending full voltage to the igniter during startup; if not, and the wiring is good, the board may be faulty.
  • K
    Kirk DavisSep 5, 2025
    Why does my Ashley AP5660L Wood stove door glass have soot buildup and lazy flame?
    • J
      Joseph StarkSep 5, 2025
      The vent pipe (including air intake) might be dirty or partially blocked, restricting airflow. The intake butterfly valve could be set too low. Check for blocked burn pot holes and clean the burn pot and housing after the unit cools (following ash disposal instructions). Also, ensure the combustion/exhaust blower is operating; if not, test it by applying 120 volts directly to the exhaust blower motor, and replace the motor if it doesn't work. Poor fuel quality can also cause this issue, so try a different brand of pellets.
  • K
    Kelly WallaceSep 4, 2025
    What to do if my Ashley AP5660L Wood stove heater will not shut off?
    • C
      carrollcraigSep 4, 2025
      If you're using a room thermostat, ensure it's set lower than the room temperature. Try disconnecting one of the wires to the exhaust temperature sensor; the heater should shut off, indicating the sensor needs replacement. You can also try to depress the ON/OFF button to 'OFF'.
  • M
    micheal75Sep 2, 2025
    How to troubleshoot Ashley Wood stove that will not light?
    • M
      mary93Sep 2, 2025
      First, ensure the Ashley Wood stove is properly plugged into a functioning wall outlet. If it still won't light, unplug it and inspect all electrical connections using the wiring diagram in the manual. Also, check the fuse on the circuit board and make sure that if a thermostat is connected, it's set to call for heat.
  • C
    Christine GarnerSep 1, 2025
    Why does the convection blower shut off and come back on in my Ashley Stove?
    • D
      dwhiteSep 1, 2025
      If the convection blower on your Ashley Stove shuts off and comes back on, it might be overheating. Try cleaning any dust off the windings and fan blades. If that doesn't help, the blower itself may be faulty. It could also be a circuit board malfunction. Test the current going to the convection blower; if power is being sent when it's shut off, the control board is fine, but if there's no power, the control board is likely bad.
  • A
    Amanda HickmanAug 31, 2025
    How to stop smoke smell coming back into home from Ashley Stove?
    • J
      Jessica JenningsAug 31, 2025
      If you're experiencing a smoke smell coming back into your home from your Ashley Stove, check for leaks in the vent pipe system, sealing all connections with high-temperature RTV silicone and UL-181-AP foil tape. Also, inspect the gaskets on the combustion blower to ensure they are in good condition.
  • V
    vickie83Aug 30, 2025
    Why does the glass soot up so fast on my Ashley Stove?
    • B
      bryantkimberlyAug 30, 2025
      If the glass on your Ashley Stove is sooting up quickly, several factors could be responsible. Ensure the stove and vent pipe are clean to allow proper airflow through the burnpot. Verify the vent pipe is installed correctly. Adjust the air damper; if it's too closed for the heat setting, open it more. Clean any blocked burnpot holes. Inspect the air damper assembly for damage. Check the air intake pipe for blockages. Test the combustion blower's RPM, which should be around 3000 after cleaning the blades. Finally, consider that the pellets may be of poor quality; try a different brand or wood type.

Summary

Safety Precautions

Specifications

Heating Specifications

Details on fuel burn rate, hopper capacity, and BTU output.

Dimensions

Physical measurements of the stove including height, width, and depth.

Electrical Specifications

Power requirements, including voltage, frequency, and amperage.

Installation

INSTALLATION OPTIONS

Outlines different ways the stove can be installed (freestanding, alcove, mobile home).

CLEARANCES

Specifies required distances from combustible materials for safe installation.

Installation

FLOOR PROTECTION

Requirements for non-combustible floor protector placement and size.

VENTING REQUIREMENTS

Guidelines for connecting the vent system, including clearances and pipe types.

MAXIMUM VENTING DISTANCE

Details on maximum allowable vent pipe length and number of elbows.

IMPORTANCE OF PROPER DRAFT

Explains the role of draft in stove performance and safety.

PELLET VENT TYPE

Specifies approved types of pellet vent pipe for installation.

Installation

PELLET VENT INSTALLATION

Instructions for installing pellet vent pipe, including clean-out tees and sealing joints.

PELLET VENT TERMINATION

Guidelines for where the vent pipe can and cannot terminate outdoors.

VENT TERMINATION CLEARANCES

Specifies required clearances for vent pipe termination points.

Assembly Instructions

Step-by-step guide for assembling control panel components.

Installation

HORIZONTAL EXHAUST VENT INSTALLATION

Detailed steps for venting the stove horizontally through a wall.

Installation

THROUGH THE WALL INSTALLATION (RECOMMENDED INSTALLATION)

Specific recommendations for through-the-wall venting, including Canadian requirements.

THROUGH THE ROOF;CEILING INSTALLATION

Instructions for venting the stove vertically through the roof or ceiling.

Installation

OUTSIDE AIR SUPPLY (OPTIONAL, UNLESS INSTALLING IN A MOBILE HOME)

Information on optional outside air intake systems.

Mobile Home Installation

Specific requirements and safety precautions for installing the stove in a mobile home.

Appliance Controls

PANEL;REMOTE CONTROLS

Overview of the stove's control panel and remote functions.

ON;OFF SWITCH (“POWER” BUTTON)

How to turn the stove on and off, and the ignition sequence.

LEVEL; TEMP ARROW BUTTONS

How to adjust heat levels and temperature settings.

°C;°F BUTTON

Function to switch temperature display between Celsius and Fahrenheit.

MODE (M;T) BUTTON

How to switch between manual and thermostat modes.

Operation

DO NOT USE CHEMICALS OR FLUIDS TO START THE FIRE

Warning against using improper fuels for starting the fire.

HOT WHILE IN OPERATION

Safety warning about hot surfaces and keeping children away.

DO NOT BURN

List of materials that should not be burned in the stove.

PROPER FUEL

Defines the approved type of fuel (premium grade pellets) and characteristics to avoid.

PRE-START-UP CHECK

Essential checks before starting the stove for the first time.

BUILDING A FIRE

Steps and precautions for building a fire in the stove.

Operation

FIRESTARTER

Detailed steps for initiating the fire and adjusting settings.

DAMPER CONTROL

Explanation of the damper control and how to adjust it for optimal combustion.

OPENING DOOR

Procedure and consequences of opening the stove door during operation.

ROOM AIR FAN

Information on when the room air fan activates.

IF STOVE RUNS OUT OF PELLETS

What happens when the stove runs out of fuel and the error code displayed.

REFUELING

Guidelines and safety tips for refueling the stove hopper.

SHUTDOWN PROCEDURE

Steps for properly shutting down the stove.

Maintenance

THERMODISC

Explanation of the high-temperature thermodisc and its functions.

TAMPER WARNING

Warning regarding altering the minimum low burn rate setting.

VISIBLE SMOKE

Using visible smoke as an indicator of combustion efficiency.

EXHAUST SYSTEM

Information on creosote formation and fly ash accumulation in the exhaust system.

Maintenance

Inspection and Removal

How to inspect and clean the chimney connector and chimney for creosote.

INTERIOR CHAMBERS

Burn Pot

Instructions for cleaning the burn pot and its housing.

Heat Exchanger

How to access and clean the heat exchanger clean-outs.

CLEANING

Instructions for cleaning the heat exchanger tubes.

Maintenance

LOCATING THE FRONT CLEANOUTS (CLEAN ANNUALLY)

Steps to locate and access the front clean-out ports for annual maintenance.

Maintenance

FANS - DANGER: RISK OF ELECTRIC SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT

Safety precautions for working with fans and disconnecting power.

CHECK AND CLEAN THE HOPPER

How to check and clean the pellet hopper for buildup.

DOOR AND GLASS GASKETS

Inspecting and replacing door and glass gaskets.

BLOWER MOTORS

Cleaning air holes on blower motors and the exhaust blower fan.

PAINTED SURFACES

How to clean and maintain painted surfaces.

GLASS - CLEANING, REMOVAL AND REPLACEMENT OF BROKEN DOOR GLASS

Detailed instructions for cleaning, removing, and replacing the door glass.

FALL START UP

SPRING SHUTDOWN

MAINTENANCE SCHEDULE

ASH REMOVAL - FREESTANDING UNIT

DISPOSAL OF ASHES

ASH REMOVAL

SMOKE AND CO MONITORS

Decorative Log Placement

Trouble Shooting Guide

Display is Flashing “E1”

Troubleshooting steps for error code E1, related to convection blower overheating.

Trouble Shooting Guide

Display is Flashing “E2”

Troubleshooting steps for error code E2, related to airflow or vacuum switch issues.

Trouble Shooting Guide

Display is Flashing “E3”

Troubleshooting steps for error code E3, related to hopper issues or auger jams.

Display is Flashing “E4”

Troubleshooting steps for error code E4, related to ignition failure or proof of fire issues.

Trouble Shooting Guide

Display is Flashing “E5”

Troubleshooting steps for error code E5, related to thermostat sensor issues.

Stove Feeds Pellets, But Will Not Ignite

Diagnosing why the stove feeds pellets but fails to ignite.

Trouble Shooting Guide

Smoke Smell Coming Back Into The Home

Diagnosing and resolving issues causing smoke smell.

Convection Blower Shuts Off And Comes Back On

Troubleshooting why the convection blower cycles on and off.

Stove will not feed pellets, but fuel feed light comes on as designed

Diagnosing issues when the stove fails to feed pellets.

Trouble Shooting Guide

High limit switch keeps tripping

Troubleshooting why the high limit switch repeatedly trips.

GLASS SOOTS UP AT A VERY FAST RATE

Addressing rapid soot buildup on the glass and related operational issues.

Parts List

Parts List

Parts List

Listing of various replacement parts with part numbers and quantities.

Wiring Diagram

Limited Warranty

WARRANTY CONDITIONS

Conditions under which the warranty is valid.

CLAIM PROCEDURE

Steps to follow when requesting warranty service.

WARRANTY EXCLUSIONS

List of situations and damages not covered by the warranty.

LIMITATIONS OF LIABILITY

Legal limitations on liability and disclaimers.

WARRANTOR

Information about the warranty provider.

Service Record

How To Order Repair Parts

Ashley AP5660L Specifications

General IconGeneral
ModelAP5660L
CategoryWood Stove
EPA CertifiedYes
MaterialSteel
ColorBlack
Efficiency75%