23
FAULT INDICATIONS
INDICATOR LAMPS
INDICATION DISPLAY TYPE OF FAULT ACTION
DOOR IS OPEN PREVENTING START OF THE SELECTED CLOSE THE DOOR
PROGRAMME(NORMAL FOR THIS TYPE OF MACHINE)
ELEMENT MALFUNCTION CONSULT SERVICE
TOO MUCH WATER IN THE MACHINE SEE SETTING OF WATER /
DRAIN PUMP
A SENSOR ERROR HAS OCCURRED CONSULT SERVICE
WATER INLET FAULT CHECK WATERINLET TAP
TROUBLE-SHOOTING PROGRAMME
It will be possible for you to locate the fault if the machine is not working properly. This facilitates the
work of the repair man and reduces repair time. To start the trouble-shooting programme, press the
Temperature selection button five time within 15 seconds. The lamps will flash alternately.
Then press the relevant symbol to see if the appertaining component according to the table below is
working. (Press Start to exit the test programme).
SYMBOL TESTS THE FOLLOWING WILL HAPPEN AFTER CLOSING THE
DOOR IF THERE IS NOTHING WRONG
WATER INLET VALVE WATER CAN BE HEARD ENTERING
DETERGENT/RINSE-AID DISPENSER THERE WILL BE A CLICK, AND DETERGENT/RINSE AID WILL BE
DISPENSED
HEATING ELEMENT THE ELEMENT HEATS UP. N.B. DO NOT TOUCH THE ELEMENT
CIRCULATION PUMP THE PUMP STARTS
DRAIN PUMP+FAN MOTOR THE PUMP STARTS AND BLOWS OUT AIR BELOW THE LOWER
LEFT CORNER OF THE DOOR