MPS-Series – Installation Guide
U-0664-0174.doc – Issue: 07 complete, approved
Page 13 of 24
10. Route the cables through the cable strain relief guides at the bottom of the microphone and re-fit the
cover; see Figure 17 (page 18).
Note that a dedicated cable strain relief guide is provided for the audio input/output cables. The
contact input/output cables can use the standard cable strain relief guides if required.
!
!
If the MPS microphone is to be used as an Emergency Microphone, ensure that the unit’s IP30
rating is preserved by:
fitting any unused 3.5 mm jacks with an anti-dust cap plug (supplied) and
fitting any unused large cable strain relief guides with a blanking sponge cord (supplied).
11. Use the drilling detail drawings in Figure 10 (page 13) to fix the M0664_80 wall bracket to the wall or
desk/console.
Figure 10 Wall-mounting: mounting hole and Right-Hand Side Bracket position
WALL-MOUNTING
M0664_80 WALL-MOUNT BRACKET
DRILLING CENTRES
ADDITIONAL PAIR OF HOLES REQUIRED
WHEN MOUNTING MICROPHONES WITH
MPX10 10-BUTTON EXPANSION MODULE(S)
USING A M0664_81 RIGHT-HAND BRACKET
140.00 mm
M0664_80
WALL BRACKET
M0664_81
R/H BRACKET
102.80 mm 110.00 mm
THIS DISTANCE IS CORRECT FOR
MOUNTING A MPS10 UNIT.
INCREASE THIS DISTANCE BY A FURTHER 110 mm FOR EACH
ADDITIONAL MPX10 10-BUTTON EXPANSION MODULE (e.g. FOR
A MPS20 THIS DISTANCE WOULD BE 220 mm)
DIAMETER=5.50 mm
!
!
Mount the MPS microphone
at eye height for best viewing
angle of the LCD display.