OPERATION AND SERVICE MANUAL
HYAMP
®
III
MODELS 3140 and 3160 GROUND BOND TESTERS
SERIAL NUMBER
Model
3140,3160
© Associated Research, Inc., 2015
13860 West Laurel Drive
Lake Forest, Illinois 60045-4546
U.S.A.
Item 38554
Ver 3.10
Printed April 27, 2016

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Associated Research HYAMP III 3140 and is the answer not in the manual?

Associated Research HYAMP III 3140 Specifications

General IconGeneral
Frequency Range50/60 Hz
DisplayLCD
AC Hipot Output Voltage0-5000 V
AC Hipot Output Current0 - 40 mA AC
Safety StandardsIEC 61010-1

Summary

Introduction and Safety

Warranty Policies

Details the instrument's warranty, registration, and extended warranty program.

Safety Symbols and Glossary

Explains safety symbols and defines technical terms used in the manual.

General Safety Guidelines

Emphasizes reviewing safety markings and instructions before operating the instrument.

Test Station and Operator Safety

Guidelines for safe test station setup and operator responsibilities.

Getting Started and Specifications

Unpacking and Installation

Instructions for safely unpacking, inspecting, and installing the instrument.

3140 HYAMP III Specifications

Lists the detailed functional specifications for the HYAMP III Model 3140.

3160 HYAMP III Specifications

Lists the detailed functional specifications for the HYAMP III Model 3160.

Instrument Controls

Front Panel Controls

Identifies and describes the front panel controls for both 3140 and 3160 models.

Rear Panel Controls

Identifies and describes the rear panel controls and connectors for both models.

Programming and Operation

Power Up and System Setup

Describes instrument power-up, menus, and system setup procedures.

Test Setup Procedures

Guides on setting up and configuring individual test parameters.

Performing Tests and Error Handling

Steps for executing tests, interpreting results, and handling error messages.

Remote I/O and System Integration

Remote Control and Signal Outputs

Details using rear panel connectors for remote control and monitoring.

Connecting to HYPOT III

Illustrates and describes integrating HYAMP III with a HYPOT III for testing.

Verification and Calibration

Instrument Verification

Process for verifying the proper functioning of the instrument's failure detection circuits.

Calibration Procedure

Detailed steps for calibrating the instrument to maintain accuracy.

Specific Calibration Steps

Detailed procedures for calibrating AC Current and AC Voltage for both models.

Replacement Parts List

3140 HYAMP III Parts

A list of replacement parts for the 3140 HYAMP III instrument.

3160 HYAMP III Parts

A list of replacement parts for the 3160 HYAMP III instrument.