Alerts users to operate equipment as per instructions for safety.
Details risks associated with electrical circuitry and heat.
Recommends periodic checks and safety valve testing every 3 months.
Specifies equipment is for sterilisation of biological materials only.
Explains design features reducing risk and user responsibilities for load handling.
Explains the importance and frequency of safety valve testing.
Provides a step-by-step guide for performing the safety valve test.
Details monitoring during the test and warnings for valve failure.
Defines the intended medical use and prohibits hazardous substances.
Lists numbered steps for basic operation from power on to unloading.
Describes how alarms are reported, cleared, and acknowledged.
Guides users on how to select a program from the available options.
Details system behavior after power interruptions during or before a cycle.
Details actions for "CYCLE COMPLETE - FAILED" and how to address alarms.
Provides steps to change current passwords and lists invalid password rules.
Details the initial setup process for the CFR logging system.
Guides administrators on adding new users and their settings.
Instructions for backing up audit files to a USB drive.
Guides on opening PDF files with Adobe Reader and entering passwords.
Details how to access the alarm list and clear alarms.
Describes interlocks preventing opening under pressure or overpressure cut-outs.
Covers starting interlocks, cooling locks, load sensed cooling, and dual locks.
Lists reasons the cover cannot be opened, including temperature and power status.
Specifies acceptable water types (tap water) and unacceptable (deionised/distilled).
Describes the main sterilization process controlled by temperature and pressure set-points.
Discusses recommended time/temperature relationships and temperature tolerance.
Details how sterilization time and temperature are set.
Guides on setting cooling locks to ensure safe door opening temperatures.
Details issues with water level sensors, including contact and dirt problems.
Explains how water level issues or stuck valves can lead to overheat faults.
Explains how load sensing compensates for thermal mass and ensures correct sterilisation.
Emphasizes the critical importance of correct probe positioning for accurate readings.
Lists issues like feint printing, paper loading problems, and printer head issues.
Guides on regular cleaning of the steriliser chamber, parts, and sensors.
Explains the solenoid locking pin and sensor system for door security.
Details regular checks for smooth operation and correct locking function.
Describes the thermostat and snap-switch cut-out for preventing overheating.
Lists key periodic tasks like safety valve testing and gasket checks.