EasyManua.ls Logo

Astralpool APH3 INVERBOOST - Page 36

Astralpool APH3 INVERBOOST
314 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 32 -
7.5.5. Cooling operation logic
Working
status
Working mode
Water in
temperature
For example ,
water in
temperature
Heat pump working level
1
Start-up
of heat
pump
When you select
the "Smart
working mode "
T1
Tset-1
T1
27
Standby.
2
Tset-1<T1
Tset
27
< T1
28
Silent mode-frequency F2
3
Tset<T1
Tset+1
28< T1
29
frequency
F9 -F8-F7,...,- F2
4
T1
Tset+1
T1
29
Powerful mode-F9
5
When you select
the "Silent
working mode".
T1
Tset-1
27
Standby
6
Tset-1<T1
Tset
27
< T1
28
Silent mode - frequency F2/F1
7
T1>Tset
T1>28
Smart mode -frequency F5
8
When you select
the "Powerful
working mode."
T1>Tset-1
T1>27
Powerful mode-frequency F10/F9
9
T1
Tset-1
T1
27
Standby
10
Re-start
to cool
water in
standby
status
Smart
T1
Tset-1
T1
27
Standby
11
Tset
T1 <Tset+1
28
T1 <29
Silent- frequency F2
12
Tset+1
T1 <Tset+2
29
T1 <30
Frequency: F2 -F3-F4,...,- F9
13
T1
Tset+2
T1
30
Powerful mode -frequency F9
14
Silent
Tset<T1
Tset+1
28< T1
29
Silent mode-frequency F2/F1
15
T1
Tset+1
T1
29
Smart mode-frequency F5
16
Powerful
T1
Tset+1
T1
29
Powerful mode-frequency F10/F9
17
T1
Tset-1
T1
27
Standby
7.6. Parameter checking or setting
7.6.1 Press 5S and then press to check the parameter from d0-d14.
Code
Parameter
Range
Remark
d0
IPM module temperature
0-120
Real value
d1
Water inlet temp.
-9℃~99
Real value
d2
Water outlet temp.
-9℃~99
Real value
d3
Ambient temp.
-30℃~70
Real value<-9 flash
d4
Frequency limitation code
0,1,2,4,8,16
Real value
d5
Coil temperature
-30℃~70
Real value<-9 flash
d6
Gas exhaust temperature
0℃~125
Real value
d7
Step of EEV
099
N*5
d8
Compressor running frequency
099Hz
Real value
d9
Compressor current
030A
Real value
d10
Current fan speed
0-1200 rpm
Real value
d11
Error code for last time
All error code
d12
MODBUS COM
0 - 5
Only Modbus function
d13
MODBUS ID Address.
1 - 88
Only Modbus function
d14
Product code parameter
001- 999
Only Modbus function
7.
7.
7.
Start-up
Start-up
Start-up
of
of
of
the
the
the
Heat
Heat
Heat
Pump
Pump
Pump

Table of Contents

Related product manuals