Model | BLPAM100 |
---|---|
Category | Heat Pump |
Heating Capacity | 10 kW |
Operating Temperature Range | -5°C to 43°C |
Refrigerant | R410A |
Power Supply | 230V/50Hz |
Water Flow Rate | 3 m³/h |
Crucial guidelines for safe and effective operation, installation, and maintenance of the heat pump.
Personnel must be familiar with instructions and check unit for transport damage. Avoid heat sources and flammable materials.
Read safety instructions before any manipulation. Incorrect manipulation can cause deadly injuries or serious damage to user and unit.
Install away from flammable gas. Use 30mA differential breaker. Ensure condensers are drained. Verify network compatibility.
Determine unit location. Secure unit on hard base. Protect from sun/heat. Ensure clear space around unit. Direct air away.
Connect PVC piping to heat pump inlet/outlet via by-pass after filter and before water treatment. Use provided fittings.
Power from sole circuit with protection components. Install by qualified professional. Link to safety earth circuit. Ensure correct cable installation.
List and explanation of various alarm codes (A11, A12, A15, A21, A22, A99) displayed by the controller.
Details on setting controller parameters such as temperature, defrosting, and water pump control via specific codes.