17/07/2013
INSTALLATION AND
OPERATING INSTRUCTIONS
Melbourne: 03 8796 8600 Gold Coast: 07 5552 2600 Perth: 08 9350 2600
Sydney: 02 9853 2100 Townsville: 07 4750 3100 sales@astralpool.com.au
Brisbane: 07 3308 5400 Adelaide: 08 8152 7600 www.astralpool.com.au
Bolero ND
Cleaner
INSTALLATION AND OPERATING INSTRUCTIONS I INSTALLATION AND OPERATING INSTRUCTIONS
Astral Heat
Pumps

Questions and Answers

  • M
    Mary SimonAug 7, 2025
    How to troubleshoot an Astralpool Heat Pump that will not start?
    • N
      nchoiAug 7, 2025
      If your Astralpool Heat Pump isn't starting, begin by ensuring the power to the heater is on and the pump is running. If the pump isn't running, start it. Check for any leaks or issues with the non-return valve if the pump is airlocked. Also, verify the filter is clean and the pump strainer basket isn't clogged. If the heater control is defective, shut off the electrical supply and call for service. Ensure the thermostat is on and set to the correct setpoint, adjusting the set temperature as needed based on the water temperature. If a fault condition is displayed due to the water being too hot, refer to the fault indication table.
  • B
    browndeborahAug 22, 2025
    Why is my Astralpool Heat Pump short cycling?
    • C
      Curtis BarnesAug 22, 2025
      Short cycling (rapid on and off operation) in your Astralpool Heat Pump can be due to several reasons. First, check for insufficient water flow by cleaning the filter and pump strainer. Second, defective wiring can cause this issue, so repair or replace the wiring if needed. Finally, a defective high limit or thermostat could be the culprit, requiring repair or replacement.

Summary

Safety Rules for Heat Pump Use

Operating Instructions

Digital Thermostat Operation

Operating Principles Explained

Explains temperature control modes, compressor delay, defrosting, and pump control.

Maintenance Procedures

Installation Requirements

Installation Personnel and Regulations

Requirements for authorized installers and adherence to local wiring rules.

Clearances for Airflow and Access

Minimum required clearances around the heater for proper airflow and service access.

Electrical Connection Guidelines

Recommendations for licensed electricians and RCD circuit breaker protection.

Guide to Heat Pump Noise and Location

Determining Distance to Neighbours Boundary

Explains a method to calculate the required distance based on noise factors.

Noise Distance Calculation Example

An example calculation demonstrating how to determine minimum installation distance.

Troubleshooting Guide

Heater Will Not Start

Lists possible causes and remedies for the heat pump failing to start.

Heater Short Cycling

Lists possible causes and remedies for rapid on/off operation of the heat pump.

Wiring Diagrams

Warranty Information

AstralPool Product Warranty

Details the warranty terms and conditions for Astral Pool Heat Pumps.

Astralpool BPM600A Specifications

General IconGeneral
ModelBPM600A
CategoryHeat Pump
Maximum Water Temperature40°C
RefrigerantR410A
Power Supply230V/50Hz
Noise Level50 dB